EBS CPX200NB Installation And Programming Manual page 36

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

o 1 – Quiet signalling of time for entering (during counting the time for leaving, the
buzzer in a keypad is not active)
o 2 – Quiet signalling of time for leaving (during counting the time for leaving, the
buzzer in a keypad is not active)
 6 – auto-arming time (DEC type parameter, time of day written in the 24-hour
notation in the form HHMM),
 7 – auto-arming option (BIT type parameter):
o 1 – auto-arming activation/deactivation
 8 – auto-disarming time (DEC type parameter, time of day written in the 24-hour
notation in the form HHMM),
 9 – auto-disarming option (BIT type parameter):
o 1 – auto-disarming activation/deactivation
Notes:
Execution of complex function 3006 (auto-arming time for all paritions) will copy
activation/deactivation option from the first partition to the second partition.
Execution of complex function 3007 (auto-arming activation/deactivation for all paritions)
will copy auto-arming time from the first partition to the second partition.
Execution of complex function 3008 (auto-disarming time for all paritions) will copy
activation/deactivation option from the first partition to the second partition.
Execution of complex function 3009 (auto-disarming activation/deactivation for all
paritions) will copy auto-disarming time from the first partition to the second partition.
If the time in the device is set forward (eg. when the time is changed to Daylight saving
time), and arming or disarming time is in the period which has been ommited, then the
hour will be not used. Eg. If the auto-arming time is set to 2:30, and time was changed
forward from 2:00 to 3:00, the control panel will not arm.
Examples:
a) change of a single parameter – assigning 1, 2, 3 zones to the first partition:
b) change of time for leaving both partitions into 60 seconds:
c) change of many parameters at the time for partition 2 using complex function –
zones 2, 4, 5 and output 1 to belong to partition 2, time for leaving the one to be
45 seconds, alarm time in partition 2 to be 120s and signalling of time for entering
and leaving was quiet:
Note:
parameters at the time) after the parameter is entered and confirmed
with
the system waits for entering another parameter, and so on, until all
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
In
case
of
complex
, the parameter is saved in the configuration memory and