EBS CPX200NB Installation And Programming Manual page 33

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

o 8 – perimeter
o 9 – perimeter exit
o 14 - arming/disarming by state change (available since the firmware ver. 2.10.0)
2 – delay in seconds for the circuit of selected "delay" response type (DEC type
parameter). For other response types the parameter is irrelevant.
3 – operation mode (DEC type parameter):
o 0 – unused circuit
o 1 – NC mode
o 2 – NO mode
o 3 – EOL/NC mode
o 4 – EOL/NO mode
o 5 – DEOL/NC mode
o 6 – DEOL/NO mode
o 7 – Wireless mode
4 – number of alarms after which the zone will be automatically blocked until re-
arming (DEC type parameter). If 0, zone will not be blocked.
 5 – zone options (BIT type parameter):
o 1 – circuit ignored during arming – i.e. can be violated during partition arming
(e.g. delay circuits shall be set to that option)
o 2 – generates alarm when violated after arming
o 3 – interlocking the zone (bypassing zone) if the zone violated when arming
(parameter "After time for exit")
6 – sensitivity in milliseconds, i.e. after what time the input is considered to change
its status – default value; 400ms
Examples:
a) change of a single parameter – operation mode of number 2 zone into NO
operation mode:
b) change of sensitivity of all zones into 200 milliseconds:
c) change of many parameters at the time for zone 1 using complex functions – zone
1 is to be set as immediate circuit, in NC mode, to be blocked after 8 violations
and generate alarm when violated after arming, with the 500ms sensitivity:
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
... ...
33 / 116