2 – Help alarm activated
Note: Alarms memory is cleared after the system is armed.
5.9.

FAULTS MEMORY

The function displays faults that are present in the system. When the function is activated,
SYSTEM and PROG LEDs are flashing slowly and all faults that are currently present in the
system are displayed. LEDs 1 – 8 display information on the cause of fault. To clear the
faults memory, press
Faults description:
Sabotage of zones
1 –
To display more detailed information about sabotage of zones, press
1 – Sabotage of zone 1
2 – Sabotage of zone 2
7 – Sabotage of zone 7
To return to the main fault menu, press
Fault of outputs 1 – 3
2 –
To display more detailed information about fault of outputs, press
1 – Fault of output 1
2 – Fault of output 2
3 – Fault of output 3
To return to the main fault menu, press
Fault of feeding outputs
3 –
To display more detailed information about fault of feeding outputs, press
1 – Fault of feeding output + KP
2 – Fault of feeding output +AUX1
3 – Fault of feeding output +AUX2
To return to the main fault menu, press
AC fault
4 –
No more detailed information.
Battery fault
5 –
No more detailed information.
ATS fault
6 –
No more detailed information.
7 – Other damages
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
- Display of faults memory
. To exit without clearing the faults memory, press
.
.
.
.
button.
button.
button.
26 / 116