EBS CPX200NB Installation And Programming Manual page 108

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

(counting from 0) means the output 1, bit 2 means the output 2 and bit 3
means the output 3. If the output is enabled, the bit is set.
batteryVoltage – battery voltage in mV (12000 = 12V). If the battery is not
connected, the readings may be incorrect, and be around 9V (9000)
powerSupplyVoltage – AC voltage at AC terminals of CPX200NB (downstream
the transformer) in mV (18000 = 18V).
silentAlarms is a bit-vector indicating the quiet alarm memory since the last
arming (arming cancels the alarm memory). Bit 1 (counting from 0),
corresponds to the zone 1, ... bit 7 corresponds to the zone 7.
zonesComFailures – is a bit-vector indicating the communication failures
between wireless detectors and control panel. Bit 1 (counting from 0),
corresponds to the zone 1, ... bit 7 corresponds to the zone 7. In CPX200NB
system this field is set to 0.
zonesPowerFailures – is a bit-vector indicating detectors power failures in
wireless detectors (means low battery in wireless detectors). Bit 1 (counting
from 0), corresponds to the zone 1, ... bit 7 corresponds to the zone 7. In
CPX200NB system this field is set to 0.
partitionsStayAway – is a bit-vector indicating partitions armed in stay mode.
Bit 0 corresponds to partition 1. Bit 1 corresponds to partition 2. If a bit is
set, it's partition is armed in stay mode. Otherwise it is armed in away mode.
This parameter values are valid only for armed partitions.
CPGETSTATUS:EPERMISIONS
If the specified password is incorrect
CPGETSTATUS:ENOT_ALLOWED
If the command was sent via open SMS
CPDELUSER:EFORMAT
If the format of the sent command is incorrect
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
108 / 116