Access To Alarm And Fault Memory Requires Authorization; Alarms And Inputs Interlocking States Are Not Displayed; Temporary Keyboard Lock After Three Access Failures; Use Duress Code - EBS CPX200NB Installation And Programming Manual

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

8.4.4.

Access to alarm and fault memory requires authorization

Selecting this option enables limitation to access to alarm memory and fault memory.
Checking alarm memory and fault memory will be available only after entering user code.
This option must be enabled in order to comply with EN 50131 standard requirements for
Grade 2.
8.4.5.

Alarms and inputs interlocking states are not displayed

Selecting this option disables display alarms and inputs interlocking states. This option
must be enabled in order to comply with EN 50131 standard requirements for Grade 2.
8.4.6.

Temporary keyboard lock after three access failures

Selecting this option enables keypad blocking after entering invalid codes. The keypad
will be blocked for 90 seconds, after entering an invalid code three times. After this
period, another lock will occur after entering a wrong code three times. The counter of
invalid codes will be reset after a correct code is entered (e.g. after entering invalid code
two times). This option must be enabled in order to comply with EN 50131 standard
requirements for Grade 2.
8.4.7.

Use duress code

Duress code is used to inform the monitoring station about a distress event. Each user
has his own duress code.
NOTE: Firmware versions older than 2.1.0 do not support the duress
code. Upgrading the Firmware to version 2.or newer one has to make
sure that there are no conflicts between existing users and their
duress codes.
8.4.8.
Show partition arming mode instead of inputs interlocking
states
Show partition arming mode instead of inputs interlocking states. By default systerm will
show violated and interlocked zones on diodes 1-8. Setting this option will tell the system
to show partitoin armind mode on diodes 1-2. Zones states will no longer be available.
Display scheme:
Led off – partition disarmed
Led on – partition armed in away mode
Led blinking – partition armed in stay mode
NOTE – this option is available only when
displayed
option is inactive.
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
Alarms and inputs interlocking states are not
71 / 116