Commands For Managing The Partitions, Zones And Outputs - EBS CPX200NB Installation And Programming Manual

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

11.1.4. Commands for managing the partitions, zones and outputs

11.1.4.1. CPGETSTATUS
Format:
CPGETSTATUS[=password]
Limitations:
You must know the administrator or user password. Can be executed by
ATS, administrator or user. If the command comes from ATS and was not
authorized with a code, enter the password.
Description
password is the system administrator or user password. The command
returns:
CPGETSTATUS:Ready,CurrentPartitionAlarms,alarmHistory,otherAlarmHistory,
zoneTampers,keypadTampers,zones,zonesLock,partitions,outputs,
batteryVoltage,powerSupplyVoltage,silentAlarms,zonesComFailures,
zonesPowerFailures,partitionsStayAway
Where:
Ready takes the value 1 if the system is ready for arming , 0 if it is not
ready.
CurrentPartitionAlarms is a bit-vector determining whether the current
partitions are in alarm condition. Bit 0 corresponds to the first partition, bit 1
corresponds to the second partition.
alarmHistory a bit-vector indicating the alarm memory from the last arming.
Bit 1 (counting from 0), corresponding to the zone 1,... bit 7 corresponds to
the zone 7.
otherAlarmHistory a bit-vector indicating the additional alarm memory from
the last arming. Bit 1 (counting from 0), corresponding to the tamper keypad
1, bit 2 corresponds to the tamper keypad 2, bit 3 corresponds to the tamper
keypad 3, bit 7 corresponds to the alarm from remote controls.
zoneTampers is a bit-vector indicating the zone tampering. Bit 1 (counting
from 0) means the zone 1.
keypadTampers is the alarm from the keypads tampering. Bit 0 means the
keypad 1.
zones – means the current status of the zones. It is a bit-vector, where the
bit 1 (counting from 0) means the zone 1, bit 2 means the zone 2, etc. If the
zone is impaired, the bit is set.
zonesLock – means the current status of the zone blockade. It is a bit-vector,
where bit 1 (counting from 0) means the zone 1, bit 2 means the zone 2,
etc. If the zone is blocked, the bit is set.
partitions – means the current status of the partitions. It is a bit-vector,
where bit 0 means the partition 1, the bit 1 the partition 2 (otherwise than
for the zones and outputs where bit 1 means the zone/output 1). If the
partition is armed or counts down, the time to output the corresponding bit is
set.
outputs – means the current status of outputs. It is a bit-vector, where bit 1
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
107 / 116

Advertisement

Table of Contents
loading

Table of Contents