Command syntax
Command description
Feedback message
Feedback message
description
Command syntax
Command description
Feedback message
Feedback message
description
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
Getting the name of partition
XXXX GETNAME=PARTITION,NR
Acquiring the name of the partition
XXXX – user code
NR – number of the partition, possibile values: 1 or 2
Example: 1234 GETNAME=PARTITION,1
GETNAME=PARTITION,NR,VALUE
or
GETNAME:ERROR
GETNAME=PARTITION,NR,VALUE – partition name
GETNAME:ERROR – command rejected by the system
Setting the phone number
XXXX SETTELNUM=ID,NUMBER
Setting the phone number for pointed index on the
phone number list
XXXX – user code
ID – index of phone number on the list, possible
values: 1 to 10
NUMBER – phone number, on which the texts will be
send
Example: 1234 SETTELNUM=3,800123456
SETTELNUM:OK
or
SETTELNUM:ERROR
SETTELNUM:OK – command accepted
SETTELNUM:ERROR – command rejected by the
system