EBS CPX200NB Installation And Programming Manual page 112

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

11.1.4.5. CPZONESLOCK
Format:
Limitations:
Description
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
CPZONESLOCK=zones[,password]
You must know the administrator or user password. Can be executed by
ATS, administrator or user. If the command comes from ATS and was not
authorized with a code, enter the password.
Blocks permanently the given zones. It generates the events
INPUTx_LOCK.
zones is a bit-vector indicating the zones, which one wants to block. Bit 1
(counting from 0) means the zone 1. Sending a command with the
argument of zones equal to 0, has no sense, since it does not change
anything. Password is the system administrator or user password, who has
authorizations to the partition containing the blocked zones.
The command returns:
CPZONESLOCK:EOK,zones
If the command is executed
CPZONESLOCK:ENOT_ALLOWED
If the command was sent via open SMS
CPZONESLOCK:EFORMAT
If the format of the sent command is incorrect
CPZONESLOCK:EPERMISIONS
If the user has not authorization to the proper partition
CPZONESLOCK:ENOT_EXISTS
If the user with the specified password does not exist
112 / 116