3. ARMED LED (red):
Flashing light – means that time for exit in any of partitions is counted.
Constant light – at least one partition is armed
Off – partitions disarmed.
4. SYSTEM LED (yellow):
Flashing light - means that in the control unit's memory there are faults that has already
ceased (there was power loss, but it has already restored).
Constant light – there is a fault in the system that was not removed.
Off – no fault in the system.
5. PROG LED (blue):
Flashing slowly – service function is activated and it is one of the user functions.
Flashing – data will be entered.
Constant light – installer service function is activated.
6. 1 - 16 LEDs (red)
When LED goes on during normal operation, it means that the line it is assigned to was
disrupted. Flashing LED means the zone was interlocked. After activating service
functions, LEDs display data.
7. Screwed Connectors
The connectors for connecting cables joining the keypad with the alarm control unit.
8. Cable Entry
It is a place for entering the connection cables.
9. Assembly Holes
The keypad was equipped with four round assembly holes for proper fastening the
keypad.
10.
Casing Opening Latch
To open the casing it is recommended to use flat 2.5-5mm screwdriver. Insert it slightly
in indicated hole and gently perform a lever movement toward the rear side of the
casing.
11.
Anti-Sabotage Switch
After the keypad is assembled the switch contact is closed. Unauthorized disassembly of
the keypad will send the message to the alarm control unit. In order to eliminate surface
unevenness, a spring is located on the switch lever.
12. - 14. Emergency Buttons
See item 5.13
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
EMERGENCY BUTTONS
17 / 116