EBS CPX200NB User Manual

Alarm control unit
Hide thumbs Also See for CPX200NB:

Advertisement

ALARM CONTROL UNIT
EN
CPX200NB
User manual
Version of the manual:
Date of issue:
Firmware version:
GPRS transmitter configurator version:
OSM server version:
v1.6
2016.01.08
2.3.7
1.3.54.10
1.3.53.3

Advertisement

Table of Contents
loading

Summary of Contents for EBS CPX200NB

  • Page 1 ALARM CONTROL UNIT CPX200NB User manual Version of the manual: v1.6 Date of issue: 2016.01.08 Firmware version: 2.3.7 GPRS transmitter configurator version: 1.3.54.10 OSM server version: 1.3.53.3...
  • Page 2 DECLARATION OF COMPLIANCE We, EBS Sp. z o.o., declare with full responsibility that the present product meets all requirements provided for in the Directive 1999/5/EC of European Parliament and Council dated 9 March 1999 The copy of the “Declaration of Compliance” can be found at http://www.ebs.pl/en/certificates/...
  • Page 3 TESTING THE OUTPUTS ....................20 7.11. DURESS CODE ......................20 7.12. EMERGENCY BUTTONS ....................20 7.13. TEXT MESSAGES ......................21 THE BEHAVIOR OF THE SYSTEM IN COMPATIBILITY MODE FOR GRADE 2 ....30 CHANGE HISTORY ...................... 30 CPX200NB ALARM CONTROL UNIT – USER MANUAL 3 / 30...
  • Page 4: Introduction

    1. INTRODUCTION Thank you for choosing EBS alarm control unit. CPX200NB is a simple, functional alarm control unit integrated with GSM/GPRS/SMS transmitter, intended for small- and medium- sized facilities. The central unit is equipped with 3 outputs and 7 wired zones with the possibility to be divided into 2 partitions.
  • Page 5: Control Unit Functions

     Remote through GPRS, SMS or CSD USERS  1 admin code (main)  1 service code  8 user codes  Possibility to restrict the scope of authorization to a few codes only CPX200NB ALARM CONTROL UNIT – USER MANUAL 5 / 30...
  • Page 6: Electrical Characteristic

    Lead-acid 12V Low voltage – event treshold: Voltage battery cut off level: below 9V Working temperature: -10ºC to +55ºC Working humidity: 5% to 93% PCB dimensions: 152mm x 78mm x 30mm CPX200NB ALARM CONTROL UNIT – USER MANUAL 6 / 30...
  • Page 7: Keypad Specification

    99 x 82 x 19 mm Keypad type: LED, 16 status LEDs, 4 mode LEDs (ALARM, ARMED, SYSTEM, PROG) Button layout: Standard telephone keypad 3 x 4 buttons Drawing 1. KP16 Keypad CPX200NB ALARM CONTROL UNIT – USER MANUAL 7 / 30...
  • Page 8 Connectors for connecting cables joining the keypad with the alarm control unit. 8. Cable Entry It is a place for entering the connection cables. 9. Assembly Holes The keypad was equipped with four round assembly holes for proper fastening the keypad. CPX200NB ALARM CONTROL UNIT – USER MANUAL 8 / 30...
  • Page 9 After the keypad is assembled the switch contact is closed. Unauthorized disassembly of the keypad will send the message to the alarm control unit. In order to eliminate surface unevenness, a spring is located on the switch lever. CPX200NB ALARM CONTROL UNIT – USER MANUAL 9 / 30...
  • Page 10: Arming The System

    If perimeter zone is not violated during the exit time countdown, partition will remain armed in the stay mode. Works only with KP16 keypad CPX200NB ALARM CONTROL UNIT – USER MANUAL 10 / 30...
  • Page 11: Away Mode

    2 – Damage of signalling device or signalling device active 3 – Damage of internal connection or sabotage 4 – AC power supply damage 5 – Battery damage 6 – ATS damage 8 – Other damages CPX200NB ALARM CONTROL UNIT – USER MANUAL 11 / 30...
  • Page 12: Disarming The System

    . 3 beeps will confirm the code. Also, the system will be disarmed. 2. In order to identify the alarm type, please refer to ALARMS MEMORY chapter of the present manual. CPX200NB ALARM CONTROL UNIT – USER MANUAL 12 / 30...
  • Page 13: Partition Handling

    Enter the correct code once again. 2. If partition arming in the away/auto mode was selected, the keypad will indicate counting the time for leaving the facility. Leave the facility before the CPX200NB ALARM CONTROL UNIT – USER MANUAL 13 / 30...
  • Page 14 3. If the partition arming in the stay mode was selected, system will arm immidiately. ARMED LED will turn on. 4. If partition disarming is selected, the relevant partition will be immediately disarmed. CPX200NB ALARM CONTROL UNIT – USER MANUAL 14 / 30...
  • Page 15: User Functions

    3 – Keypad tamper 3 Other alarm source types -> Emergency button used: 1 – Fire alarm activated 2 – Help alarm activated Note: Alarms memory is cleared after the system is armed. CPX200NB ALARM CONTROL UNIT – USER MANUAL 15 / 30...
  • Page 16: Faults Memory

    To return to the main fault menu, press AC fault 4 – No more detailed information. Battery fault 5 – No more detailed information. ATS fault 6 – No more detailed information. CPX200NB ALARM CONTROL UNIT – USER MANUAL 16 / 30...
  • Page 17: Zone Blocking

    3 beeps will confirm the successfully entered function. Default admin code: 1111. Note: Individual code cannot be the same; if any code is the same as another one, it will not be recorded. CPX200NB ALARM CONTROL UNIT – USER MANUAL 17 / 30...
  • Page 18: User Delete

    5. Successful deletion of a user will be confirmed with 3 beeps, otherwise a constant sound will be emitted. 7.6. CHANGE OF USER CODE The user can change its code here. 3 beeps will confirm the successfully entered function. CPX200NB ALARM CONTROL UNIT – USER MANUAL 18 / 30...
  • Page 19: Programming Time

    In any moment you can press to exit without saving changes. 7.9. TESTING THE ZONES The function allow user to test zones and detectors connected to zones input. <User code> <Duration of test> CPX200NB ALARM CONTROL UNIT – USER MANUAL 19 / 30...
  • Page 20: Testing The Outputs

    Duress code is disabled by default. It can be enabled by the installer or by the configuration program. 7.12. EMERGENCY BUTTONS The keypad of CPX200NB has 3 function keys. Pressing and holding for 3 seconds one of these keys will generate an alarm corresponding to the key: –...
  • Page 21: Text Messages

    For SMS to be accepted, the phone number from which the text is being send, has to be enlisted on the allowed numbers list. CPX200NB can store up to 10 phone numbers and up to 32 text messages. If, for any reason, the SMS can not be...
  • Page 22 VALUE – new name of the partition Example 1: 1234 SETNAME=PARTITION,1,Cellar Example 2: 1234 SETNAME="PARTITION,2,Kids Room" Feedback message SETNAME::OK or SETNAME:ERROR Feedback message SETNAME::OK – command accepted description SETNAME:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 22 / 30...
  • Page 23 NUMBER – phone number, on which the texts will be send Example: 1234 SETTELNUM=3,800123456 Feedback message SETTELNUM:OK SETTELNUM:ERROR Feedback message SETTELNUM:OK – command accepted description SETTELNUM:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 23 / 30...
  • Page 24 ID – index of text, possible values: 1 to 32 MESSAGE – content of the text message Example: 1234 SETMESSAGE=4,Robbery Feedback message SETMESSAGE:OK or SETMESSAGE:ERROR Feedback message SETMESSAGE:OK – command accepted description SETMESSAGE:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 24 / 30...
  • Page 25 ID – index of text, possible values: 1 to 32 Example: 1234 GETMESSAGE=30 Feedback message GETMESSAGE=ID,MESSAGE GETMESSAGE:ERROR Feedback message GETMESSAGE=ID,MESSAGE – information about the description contents of text message GETMESSAGE:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 25 / 30...
  • Page 26 6 will be sent to phone numbers with indexes 1,8 and 9. Feedback message SETUSERSMS=EVENT,TELNUM,MSG_ID:OK SETUSERSMS=EVENT,TELNUM,MSG_ID:ERROR Feedback message SETUSERSMS=EVENT,TELNUM,MSG_ID:OK – description command accepted SETUSERSMS=EVENT,TELNUM,MSG_ID:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 26 / 30...
  • Page 27 Example: 1234 GETUSERSMS=ARM1 Feedback message GETUSERSMS=EVENT:TELNUM,MSG_ID GETUSERSMS=EVENT:ERROR Feedback message GETUSERSMS=EVENT:TELNUM,MSG_ID – description information about text message and phone number assinged to the event GETUSERSMS=EVENT:ERROR – command rejected by the system CPX200NB ALARM CONTROL UNIT – USER MANUAL 27 / 30...
  • Page 28 Zones 1…3 trigger ended (to OUTPUT3-OFF) OUTPUT1-TAMPER Fault of zones 1…3 (to OUTPUT3-TAMPER) OUTPUT1-TAMPEREND Fault of zones 1…3 ended (to OUTPUT3-TAMPEREND) POWER-FAIL Power failure POWER-OK Power failure ended BATTERY-FAIL Battery failure CPX200NB ALARM CONTROL UNIT – USER MANUAL 28 / 30...
  • Page 29 List of errors sent as feedback messages Alias name Description ERROR-PERMISSION Permission to issue this command was not granted ERROR-FORMAT Wrong command syntax ERROR-VALUE Wrong parameter value ERROR-EMPTY Parameter value missing ERROR Other error CPX200NB ALARM CONTROL UNIT – USER MANUAL 29 / 30...
  • Page 30: The Behavior Of The System In Compatibility Mode For Grade 2

    08.10.2015 / i1.4 / 2.2.0 Updated information about stay/away mode 09.11.2015 / i1.5 / 2.3.1 Updated information about stay/away mode 08.01.2016 / i1.6 / 2.3.7 Updated information about testing the outputs CPX200NB ALARM CONTROL UNIT – USER MANUAL 30 / 30...