Section 7

During Cleaning and Sanitizing

ALWAYS FOLLOW LOCAL HEALTH CODES.
Cleaning and sanitizing schedules are governed
by federal, state, or local regulatory agencies,
and must be followed accordingly. If the unit
has a "Standby mode", it must not be used in
lieu of proper cleaning and sanitizing
procedures and frequencies set forth by the
ruling health authority. The following check
points should be stressed during the cleaning
and sanitizing operations.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.

Troubleshooting Bacterial Count

j 1. Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush cleaning.
j 2. Use all brushes supplied for thorough
cleaning. The brushes are specially designed
to reach all mix passageways.
j 3. Use the white bristle brush to clean the mix
inlet hole which extends from the mix hopper
down to the rear of the freezing cylinder.
j 4. Use the black bristle brush to thoroughly
clean the rear shell bearing located at the rear
of the freezing cylinder. Be sure there is a
generous amount of cleaning solution on the
brush.
130108

Important: Operator Checklist

Important: Operator Checklist
j 5. IF LOCAL HEALTH CODES PERMIT THE
j 6. The bacteria cycle must be broken every
j 7. Properly prepare the cleaning and sanitizing
j 8. The temperature of the mix in the mix hopper

Regular Maintenance Checks

j 1. Replace scraper blades that are nicked or
j 2. Check the rear shell bearing for signs of wear
j 3. Using a screwdriver and cloth towel, keep the
38
USE OF RERUN, make sure the mix rerun is
stored in a sanitized, covered stainless steel
container and used the following day. DO
NOT prime the machine with rerun. When
using rerun, skim off the foam and discard.
Mix the rerun with fresh mix in a ratio of 50/50
during the days operation.
seven days. On a designated day of the
week, run the mix as low as feasible and
discard it after closing. This will break the
rerun cycle and reduce the possibility of high
bacteria and coliform counts.
solutions. Read and follow the label directions
carefully. Too strong of a solution may
damage the parts and too weak of a solution
will not do an adequate job of cleaning or
sanitizing.
and walk-in cooler should be below 40_F
(4.4_C).
damaged. Before installing the beater
assembly, be certain that scraper blades are
properly attached to the helix.
(excessive mix leakage in rear drip pan) and
be certain it is properly cleaned.
rear shell bearing and the female hex drive
socket clean and free of lubricant and mix
deposits.