Taylor C723 Operator's Manual page 29

Soft serve freezer
Hide thumbs Also See for C723:
Table of Contents

Advertisement

Use the arrow symbols to advance forward or
backward to view each screen. The following list
indicates the variable messages that may appear.
Press the SEL key to return to the Manager's Menu.
Faults Occurring While in AUTO or
Standby Mode
L - R HPR Therm Fail - The hopper thermistor
failed. Call for service.
L - R BRL Therm Fail - The freezing cylinder
thermistor failed. Call for service.
L - R HPR>59F (15C) - The mix temperature in the
hopper exceeded 59°F (15°C).
L - R BRL>59F (15C) - The mix temperature in the
freezing cylinder exceeded 59°F (15°C).
L - R HPR>45F (7C) AFTER 1 HR - The mix
temperature in the hopper was above 45°F (7°C)
more than one hour.
L - R BRL>45F (7C) AFTER 1 HR - The mix
temperature in the freezing cylinder was above 45°F
(7°C) more than one hour.
L - R HPR>41F (5C) AFTER 4 HR - The mix
temperature in the hopper was above 41°F (5°C)
more than four hours.
L - R BRL>41F (5C) AFTER 4 HR - The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours.
L - R HPR>41F (5C) AFTER PF - The mix
temperature in the hopper was above 41°F (5°C)
more than four hours, following a power failure.
L - R BRL>41F (5C) AFTER PF - The mix
temperature in the freezing cylinder was above 41°F
(5°C) more than four hours, following a power
failure.
Note: Refer to your local health codes regarding
temperature recommendations for procedures to
follow if these fault screens appear.
The SYSTEM INFORMATION is displayed on three
separate screens. The first screen contains the
control and software version installed in the
machine. (See Figure 38.)
Model C723
SOFTWARE VERSION
C723 CONTROL UVC4
VERSION V00.00.000
> Next
Touch the SEL symbol to advance to the next
system information screen containing the software
language version. (See Figure 39.)
Language
V3.00 English
> Next
Touch the SEL symbol to advance to the third
system information screen containing the model bill
of material and machine serial number. Touching the
SEL symbol again will return to the Manager's
Menu. (See Figure 40.)
B.O.M. C700000000
S/N
> Next
The CURRENT CONDITIONS screen displays the
current viscosity, and the hopper and barrel
temperatures. Press the SEL or MENU symbols to
return to the Manager's Menu. (See Figure 41.)
VISC
HOPPER
BARREL
25
Figure 38
Figure 39
K0000000
Figure 40
0.0
0.0
41.0
41.0
41.0
41.0
Figure 41
Important: To the Operator

Hide quick links:

Advertisement

Table of Contents
loading