Replacement of the Developer Heater
[1]
Disconnect the main power.
[2]
Drain the DEVELOPER TANK or clamp the 2 TUBES to the THERMOWELL.
[3]
Disconnect the wires to the DEVELOPER HEATER at TB2-9 and TB2-10.
When you remove the DEVELOPER HEATER from the THERMOWELL, a small amount of
developer may spill. Clean any spilled solution.
[4]
Remove the:
• 2 SCREWS
• THERMOWELL
• DEVELOPER HEATER from the THERMOWELL
H112_0099BCA
H112_0099BA
2-28
DEVELOPER
TANK
TUBE
DEVELOPER
HEATER
Removing the Thermowell
SCREW (2)
TUBE
981777