Section 5: Plumbing

General Information

CLAMP
TL-2170

Removing the DEVELOPER or FIXER HEATER and THERMISTOR

DEVELOPER THERMISTOR
DEVELOPER HEATER
FIXER HEATER
FIXER THERMOWELL
7C8285 – 28JAN98
H104_0587ACA
H104_0587AA
RECIRCULATION INPUT
FIXER THERMISTOR
DEVELOPER THERMOWELL
H104_0581GCB
H104_0581GA
Important
• When you disconnect plumbing connections, use
CLAMP TL-2170 to stop the flow of solution in the
HOSES. If you use CLAMP TL-2170, in most
cases, you will not need to drain the TANK.
• When you remove plumbing components, see this
section, as well as the COMPONENT LOCATOR
manual and the PARTS LIST for illustrations that
show the location of parts and show the parts
exploded off the components.
Important
• When you install the HEATERS or
THERMISTORS, do not overtighten the parts.
• Use only SEALANT TL-3230 when you install the
HEATERS or THERMISTORS into the
THERMOWELL. Other SEALANTS might weaken
the plastic in the THERMOWELL. See the
instructions packed with the SEALANT.
• It is not necessary to remove the THERMOWELL
from the PROCESSOR to remove the
DEVELOPER HEATER or DEVELOPER or FIXER
THERMISTORS. For access to the FIXER
HEATER:
1. Move the RECIRCULATION PUMP.
2. Move the FIXER THERMOWELL.
• Before you remove the DEVELOPER HEATER or
THERMISTOR, drain the DEVELOPER TANK to
below the recirculation input opening. (The CLAMP
TL-2170 will not work correctly on the short length
of HOSES.)
[1] See the illustration to remove the desired part.
[2] When you install the HEATERS, check that the
internal LOCATOR is positioned correctly inside
the THERMOWELL. See the illustration below.