1
2
3
4
•
•
•
•
•
•
981777
1. Transport Failure
2. Surface Artifacts
3. Abnormal Film Densities
4. Wet Films
5. Low Solution Levels
6. Overlapping of Films
5
6
•
Check the time delay. For all transport speeds, the buzzer should sound
once the trailing edge of the film has advanced 75 mm (3 in.) into the
processor.
•
Check that the tank solution levels are at the overflow weirs.
Adjust the guide shoes correctly.
NOTE: Most often in the developer turnaround. Adjust the tips of the
guide shoes in the exit turnaround as close as possible to the rack
roller above them.
•
Check for solution in the replenisher tanks. Fill if necessary.
NOTE: Do not mix more than a 2-week supply of developer replenisher.
Check that the correct bulb is in the safelight.
4-3