Rack Assemblies - Kodak M35 Service Manual

Processor
Hide thumbs Also See for M35:
Table of Contents

Advertisement

Rack Assemblies

When you remove the FIXER RACK
ASSEMBLY, install a SPLASH GUARD
between the DEVELOPER TANK and
the FIXER TANK to prevent
contamination of the developer. Use a
DRIP TRAY when you remove the
RACK ASSEMBLIES. Install the
RACK ASSEMBLIES slowly into the
TANKS.
Rollers
[1]
Remove the RACK ASSEMBLIES from the
processor.
[2]
Rinse the RACK ASSEMBLIES with warm
water, approximately 44°C (110°F).
Discoloration of the ROLLERS is normal.
[3]
If necessary, use a soft brush or:
Developer Rack
Assembly
Fixer Rack Assembly
Wash Rack Assembly
[4]
Remove the STUDS from the drive side.
[5]
Remove all the OUTER ROLLERS on the entrance side except the bottom OUTER ROLLER.
[6]
Clean the INNER and OUTER ROLLERS.
[7]
Check all SPROCKETS and GEARS for wear.
[8]
Check that all ROLLERS are straight.
[9]
Install the ROLLERS in the RACK ASSEMBLY.
[10]
Check:
• That the ROLLERS are installed correctly.
• The REWET ROLLER for wear.
• That the REWET ROLLER is smooth.
• That the REWET ROLLER touches the ROLLERS above and below it.
• The RACK ASSEMBLY for squareness. See page 2-7.
981777