Performing settings for MIDI
When the MIDI IN connector of the SIU-100/100T
and the MIDI OUT of the DMX-R100 are connected, a
scene from the SIU-100/100T can be recalled in
response to the MIDI signal.
The MIDI submenu allows you to make the following
settings related to scene recalls according to the MIDI
signal received.
• Correspondence of the program and scene number
• Specifying the MIDI channel based on program
change message received
• Setting the OMNI mode on/off
When the OMNI mode is set to ON, the specification
of the MIDI channels is ignored.
1
Enter the MIDI submenu by displaying it on the
LCD.
2
Select the item to be used so that the window is
changed using the V and v buttons.
3
Change the setting of the item selected in step 2.
To set the correspondence of the program
number to the scene number
1 Move the cursor to "PGM" using the B button,
and enter the program number using the ten
key pad or the +/– buttons.
The scene number which corresponds to the
selected program number is displayed. If there
is no corresponding scene number, the scene
number area is left blank.
Specify a program number between 1 and 127.
2 Move the cursor to "SCN" by pushing the b
button, and enter a 3 digit scene number.
Once you change the number, the unit enters
the mode where the scene number is specified,
and the scene number blinks.
To clear the correspondence, enter "000".
3 Push the ENTER button.
The scene number entered is executed and the
scene number stops blinking.
To specify the MIDI channel
Select a channel between 1 and 16, or OFF, using
the +/– buttons.
To set the OMNI mode to on or off
Select ON or OFF using the +/– buttons.
Setting the IP address and so on
The IP submenu allows you to perform the following
settings required for controlling the SIU-100/100T via
the Ethernet.
• IP ADDRESS
Sets the IP address of the SIU-100/100T.
• GATEWAY
Sets the address of the gateway assigned to the
network to which the SIU-100/100T is connected.
• SUBNET MASK
Sets the subnet mask assigned to the network to
which the SIU-100/100T is connected.
• NAME
Sets the name (up to 8 characters) of the SIU-100 or
SIU-100T to distinguish between them.
• PASSWORD
Sets the password (up to 8 characters) to perform
settings using HTTP.
• MAC ADDRESS
Displays the MAC address of the SIU-100/100T. It
cannot be set.
1
Enter the IP submenu by displaying it on the LCD.
2
Select the item to be used so that the window is
changed using the V and v buttons.
(Continued)