Error and warning messages

36.1

Error messages

Errors that occur are displayed as a coded error number in the LED-display on the front panel, and in the
"STATUS" screen page. All error messages result in the BTB/RTO contact being opened and the output stage
of the amplifier being switched off (the motor loses all torque). The motor-holding brake is activated. Errors that
are recognized by the mains supply monitoring are only reported after the servo amplifier has been enabled.
* = These error messages can be canceled by the ASCII command CLRFAULT, without making a reset. If only
these errors are present, and the RESET button or the I/O-function RESET is used, the CLRFAULT command
is also all that is carried out.
Setup Software
Number
Designation
heat sink temperature
F01*
F02*
overvoltage
F03*
following error
F04
feedback
F05*
undervoltage
F06
motor temperature
F07
v_fault (int.supply)
F08*
overspeed
F09
EEPROM
F10
Flash-EPROM
brake
F11
motor phase
F12
F13*
internal temperature
F14
output stage
F15
I²t max.
F16*
mains BTB/RTO
F17
A/D converter
F18
regen
F19*
mains phase
F20
Slot error
F21
Handling error
F22
Short circuit to earth
F23
CAN bus off
Warning
F24
F25
Commutation error
F26
Limit switch
F27
AS-Option
F28
reserved
F29
Sercos
F30
Emerg. Stop Timeout
wrong Firmware-version
F31
F32
system fault
07/03
Explanation
heat sink temperature is too high,
the limit is set by the manufacturer to 80°C
overvoltage in the DC-link circuit,
the limit depends on the mains supply voltage
message from the position controller
cable break, short-circuit, short to ground
undervoltage in DC-link,
the limit is set by the manufacturer to 100V
temperature sensor faulty or motor temperature too high,
the limit is set by the manufacturer to 145°C
internal aux. voltage not OK
motor running away, the speed is higher than permitted
checksum error
checksum error
cable break, short-circuit, short to ground
motor phase missing (cable break or similar)
internal temperature too high
fault in the power output stage
I²t max. value exceeded
2 or 3 supply phases missing
error in the analog-digital conversion
regen circuit faulty or incorrect setting
a supply phase is missing
(can be switched off for 2-phase operation)
Hardware error on the expansion card
Software error on the expansion card
40/70 amps types only: Short circuit to earth
CAN bus total communication error
Warning display as error
Commutation error
Homing error (Hardware limit switch reached)
Operating error for AS-option
reserved
Sercos error
Emerg. Stop Timeout
wrong Firmware Version
system software not responding correctly
Error and warning messages