Appendix 1 - Parallel connection (400 kW ... 1 MW sizes)
A 1.1 Introduction
To obtain a drive of more than 355 kW connect a number of single units of be-
tween 200 kW and 355 kW in parallel.
A parallel connection of several drives basically consists of one MASTER unit and
one or more SLAVE units.
Power
code
S9O25M
400kW
S9O25S
S9O26M
500kW
S9O26S
S9O27M
630kW
S9O27S
S9O32M
710kW
S9O32S
S9O27M1
900kW
S9O27S
S9O27S
S9O32M1
1 MW
S9O32S
S9O32S
Master unit
This is the only one to have the regulation card and keypad. It differs from the
standard single unit in that the power section control card (INT-P-ADV) is recon-
figured to function as MASTER and includes one or more MASTER - SLAVE (INT-
SLAVE) interface cards, one card for each slave that is connected.
The MASTER - SLAVE interface is achieved via a specific signal cable included in
the SLAVE drive packaging.
Slave unit
It differs from the standard single unit in that it has a dedicated power section
control card (INT-P-ADV) and there is no regulation card or keypad.
INT-P-ADV-MASTER card
The INT-P-ADV-MASTER card provided with one or more INT-SLAVE cards, acts
as the interface between the R-ADV regulation card and the power section of the
master unit and all the slave units. It also performs the following functions:
INT-P-ADV-SLAVE card
The INT-P-ADV-SLAVE card interfaces between the power section of the slave
unit and the master unit. It also performs the following functions:
182
Description (Designation)
ADV-72000-KXX-4-MS 04 -SI
ADV-72000-XXX-4-SL
ADV-72500-KXX-4-MS 05 -SI
ADV-72500-XXX-4-SL
ADV-73150-KXX-4-MS 06 -SI
ADV-73150-XXX-4-SL
ADV-73551-KXX-4-MS 07 -SI
ADV-73551-XXX-4-SL
ADV-73150-KXX-4-MS 09 -SI
ADV-73150-XXX-4-SL
ADV-73150-XXX-4-SL
ADV-73551-KXX-4-MS 10-SI
ADV-73551-XXX-4-SL
ADV-73551-XXX-4-SL
current signal scaling (via dip switch, factory-set)
hardware dead time compensation
alarm signal management (including local diagnostics via LED)
temperature signal management.
alarm signal management (including local diagnostics via LED)
temperature signal management.
ADV200 • Quick start up guide
Power
code
S9O25MC
ADV-72000-KXX-4- MS 04-DC- SI
400kW
S9O25SC
ADV-72000-XXX-4- SL-DC
S9O26MC
ADV-72500-KXX-4-MS 05-DC-SI
500kW
S9O26SC
ADV-72500-XXX-4-SL-DC
S9O27MC
ADV-73150-KXX-4 -MS 06-DC-SI
630kW
S9O27SC
ADV-73150-XXX-4 -SL-DC
S9O32MC
ADV-73551-KXX-4- MS 07-DC-SI
710kW
S9O32SC
ADV-73551-XXX-4- SL-DC
S9O27M2
ADV-73150-KXX-4 -MS 09-DC-SI
900kW
S9O27SC
ADV-73150-XXX-4 -SL-DC
S9O27SC
ADV-73150-XXX-4 -SL-DC
S9O32M2
ADV-73551-KXX-4- MS 10-DC-SI
1 MW
S9O32SC
ADV-73551-XXX-4- SL-DC
S9O32SC
ADV-73551-XXX-4- SL-DC
Description (Designation)