gefran ADV200 Series Quick Start Up Manual, Specification And Installation page 86

Field oriented vector ac drive for synchronous/asynchronous motors
Hide thumbs Also See for ADV200 Series:
Table of Contents

Advertisement

8. If the motor does not reach its maximum speed, self-tuning of the analog input
9. If the motor still rotates with a reference of zero, eliminate the condition by
10. To reverse the direction of rotation, keep closed the FR forward src (PAR
11. To stop the drive, open the FR forward src (PAR 1042) contact (terminals
12. If the Enable contact is opened while the motor is running, the inverter bridge
Note !
Once you have verified the correct operation of the drive-motor system, the application can be cus-
tomized by changing some of the parameters.
• Summary of parameters
The parameters used and/or modified in the Startup Wizard procedures are listed
below.
Menu PAR
16.1
16.2
16.3
16.4
16.5
16.6
16.9
16.10 2024
5.22
6.1
6.2
4.1
Proceed to step 8.
86
may be necessary': set the input signal to its maximum value and set the An
inp 1 gain tune parameter (PAR: 1508) to 1.
self-tuning the analog input offset: set the input signal to its minimum value
and set 1 for An inp 1 offset tune (PAR: 1506).
1042) contact (terminals S3 – 8) and close the FR reverse src (PAR 1044)
contact (terminals S3 – 9). The motor will start the deceleration ramp until
reaching the zero speed, after which it will reverse the direction of rotation and
move to the set speed with the acceleration ramp.
S3 – 8): the motor will start the deceleration ramp and the speed will move to
zero, but the motor will remain magnetized. To interrupt magnetization, open
the Enable contact (terminals S3 – 7).
is immediately disabled and the motor stops due to inertia.
Description
2000
Rated voltage
2002
Rated current
2004
Rated speed
2006
Rated frequency
2008
Pole pairs
2010
Rated power
2022
Autotune rotation
Autotune still
680
Full scale speed
700
Acceleration time 0
702
Deceleration time 0
550
Save parameters
ADV200 • Quick start up guide
Motor rated voltage
Motor rated current
Motor rated speed
Motor rated frequency
Number of pole pairs
Motor rated power
Self-tuning with motor rotating
Self-tuning with motor at stand-still or coupled
to the load
Maximum speed setting
Acceleration time 0
Deceleration time 0
Save parameters in the non-volatile memory

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adv200-...-dc series

Table of Contents