Installation altitude above sea level
0 ... 1000 m
Input voltage derating factor
Kv
2
Installation
altitude
m (s.l.m.)
380 Vac
≤ 2000
100%
≤ 2250
100%
≤ 2500
100%
≤ 2750
100%
≤ 3000
100%
≤ 3250
100%
≤ 3500
100%
≤ 3750
100%
≤ 4000
98%
If the voltage derating factor is not considered, may occour a drive breakdown.
Caution
K
Output Current derating factor at Ambient Temperature of:
t
20°C
25°C
: Derating factor of the input voltage based on altitudes
6)
(
Figure 9.7.1: K
2
v
1.0
0.9
0.8
0.7
0
400 Vac
100%
100%
100%
100%
100%
100%
100%
96%
93%
ADV200 • Quick start up guide
30°C
35°C
40°C
1
derating factor based on altitudes
1000
2000
K
Derating factor
(6)
V 2
Mains voltage [V]
415 Vac
440 Vac
100%
100%
100%
100%
100%
100%
100%
100%
100%
97%
99%
94%
96%
91%
93%
88%
90%
85%
45°C
50°C
0.95
0.90
3000
4000
Installation Altitude a.s.l. (meters)
460 Vac
100%
100%
98%
96%
93%
90%
87%
84%
81%
480 Vac
100%
97%
94%
92%
89%
86%
83%
80%
78%