Sizes
ADV200-DC
@540 Vdc
Heavy duty
(A)
3185
38
3220
46
4300
62
4370
75
4450
87
5550
105
5750
150
5900
180
61100
210
61320
250
71600
300
72000
385
72500
460
73150
590
73551
650
400 kW
730
500 kW
870
630 kW
1120
710 kW
1230
900 kW
1600
1 MW
1800

9.7.1 Derating factors

The derating factors shown below are applied to the rated DC output by the user.
They are not automatically implemented by the drive.
Output current derating factors
I
drive
K
(1)
1
v
K
(2)
t
K
alt
K
(4)
f
If not all of the derating factors are considered, this could result in a drive overtempera-
ture condition.
The specific alarm indicates this condition and normal drive operation is stopped.
Caution
I
Rated output current
n
(For Asynchronous motors)
@540 Vdc
@650 Vdc
Light duty
Heavy duty
(A)
(A)
46
34.2
62
41.4
75
55.8
87
67.5
105
78
150
94.5
180
135
210
162
250
189
300
225
385
270
460
347
590
414
650
531
730
585
870
657
1120
783
1230
1008
1380
1107
1800
1440
2050
1620
= I
x K
x K
x K
1
n
v
t
: Derating factor for mains voltage from 460V
ply from AFE200.
:
Derating factor for 50°C ambient temperature (1 % each °C above 40°C)
: Derating factor for installation at altitudes above 1000 meters a.s.l.. Value
(3)
to be applied at each 100 m increase above 1000 m (up to a maximum of
4000 m).
I.e.: Altitude 2000 m, K
((12*100)/100) = 88 % I
:
Derating factor for higher switching frequency
ADV200 • Quick start up guide
@650 Vdc
@540 Vdc
Light duty
Heavy duty
(A)
(A)
41.4
34
55.8
41
67.5
56
78.3
68
94,5
78
135
95
162
135
189
162
225
189
270
225
347
270
414
347
531
414
585
531
657
585
783
657
1008
783
1107
1008
1242
1107
1620
1440
1845
1620
x K
alt
f
= 1.2 *10 = 12% di derating; I
alt
n
I
Rated output current
n
(For Synchronous motors)
@540 Vdc
@650 Vdc
Light duty
Heavy duty
(A)
(A)
41
30.6
56
36.9
68
50.4
78
61.2
95
70.2
135
85.5
162
122
189
146
225
170
270
203
347
243
414
312
531
373
585
469
657
527
783
591
1008
705
1107
907
1242
996
1620
1296
1845
1458
to 480V
and power sup-
ac
ac
derated = 100 -
n
@650 Vdc
Light duty
(A)
36.9
50.4
61.2
70.2
85.5
121.5
146
170
203
243
312
373
469
527
591
705
907
996
1118
1458
1661
141

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adv200-...-dc series

Table of Contents