• Keypad
Use the LOC / REM key with the Enable input open (terminal 7 on terminal strip
T2) to control running, to stop and reverse the direction of rotation of the motor
using the operator keypad on the drive. Use the potentiometer or an analog signal
to control speed.
For information on how to use a digital speed reference, see the example on
ter
reverse the direction of rotation of the motor.
When the Enable input is closed, to enable motor running press START. The mo-
tor starts the acceleration ramp and moves to the speed set in the FWD direction.
With the motor running you can adjust the speed using the PAR 602 Dig ramp
ref 2 (or PAR 604 Dig ramp ref 3, in this case modify also the selection PAR 614
Ramp ref 3 src to PAR 604 Dig ramp ref 3), and the acceleration/deceleration
ramps using Acceleration time 0 (PAR: 700) and Deceleration time 0 (PAR:
702).
To change the direction of rotation press FWD/REV.
To stop the motor with the deceleration ramp, press STOP.
If the Enable contact is opened the inverter bridge is immediately disabled and the
motor stops for inertia
To return to control using the terminal strip commands and analog speed reference:
1.
2.
3.
Note !
For more customizations and any information that is not included in this initial customization guide, see
the description of the parameters in this manual.
104
7.3.3. The reference can have a positive or negative value, making it possible to
Stop the motor
Open the Enable terminal
Press LOC / REM key.
ADV200 • Quick start up guide
chap-