gefran ADV200 Series Quick Start Up Manual, Specification And Installation page 81

Field oriented vector ac drive for synchronous/asynchronous motors
Hide thumbs Also See for ADV200 Series:
Table of Contents

Advertisement

Step 2 - Setting motor parameter (Set motor data)
Set the rating data of the motor connected: rated voltage, rated frequency, rated
current, rated speed, rated power, power factor (cosφ).
The self-tuning procedure is described below using the data of an imaginary motor
by way of example.
T+
T -
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
Rated Voltage [V]:
Rated current [A]:
Rated speed [rpm]:
Rated frequency [Hz]:
Pole pairs:
Motor & Co.
Type: ABCDE
IEC 34-1 / VDE 0530
Motor: 3 phase
Nr
50 Hz
.
Rated voltage
380 V
I nom
Rated power
10 Hp
Power factor
Rated speed (n )
720 rpm
N
IP54
Iso Kl
F
S1
Made in ..............
T+
T-
EN
LOC
ILim
n:0
AL
STARTUP WIZARD
E
Set motor data ?
E=Yes
Down=Next
motor rated voltage as indicated on the data plate.
motor rated current, approximately, the value should not be less than 0.3 times the rated current of the
drive, output current class 1 @ 400V on the rating plate of the drive.
motor rated speed, the value must reflect the speed of the motor at full load at rated frequency. If slip is
indicated on the motor rating data, set the Rated speed parameter as follows:
Rated speed = Synchronous speed - Slip
motor rated frequency, as shown on the data plate.
Number of motor pole pairs. The number of motor pole pairs is calculated using the data on the plate and
the following formula:
P = 60 [s] x f [Hz] / nN [rpm]
Where:
p = motor pole pairs
ADV200 • Quick start up guide
12345-91
19.0 A
0.83
T+
T-
EN
LOC
ILim
n:0
AL
T+
T+
S E Q . 0 1
PA R :
2 0 0 0
1 3 . 0 1
S E Q . 0 1
E
Rated voltage
Rated voltage
Rated voltage
400
+
+
+
V
Def:
+400
Def:
Def:
T+
T-
EN
LOC
ILim
n:0
AL
T+
S E Q . 0 2
PA R :
2 0 0 2
S E Q . 0 2
E
Rated current
Rated current
11.8
+
+
A
Def:
+11.8
Def:
T+
T-
EN
LOC
ILim
n:0
AL
T+
S E Q . 0 3
PA R :
2 0 0 4
S E Q . 0 3
E
Rated speed
Rated speed
1450
+
+
rpm
Def:
+1450
Def:
T+
T-
EN
LOC
ILim
n:0
AL
S E Q . 0 4
PA R :
2 0 0 6
Rated frequency
50.0
+
Hz
Def:
+50.0
T+
T-
EN
LOC
ILim
n:0
AL
T+
S E Q . 0 5
PA R :
2 0 0 8
S E Q . 0 5
E
Pole pairs
Pole pairs
2
+
+
Def:
+2
Def:
T+
T-
EN
LOC
ILim
n:0
AL
T+
S E Q . 0 6
PA R :
2 0 1 0
S E Q . 0 6
E
Rated power
Rated power
5.50
+
+
kW
Def:
+5.50
Def:
T+
T-
EN
LOC
ILim
n:0
AL
S E Q . 0 7
PA R :
2 0 1 2
Rated power factor
0.83
+
Def:
+0.83
T-
T-
EN
EN
LOC
LOC
ILim
ILim
n:0
n:0
AL
AL
T+
E
PA R :
PA R :
2 0 0 0
1 0 0
S E Q . 0 1
Rated voltage
000000400
000000400
000000380
+
V
V
+400
+400
Def:
T-
EN
LOC
ILim
n:0
AL
T+
E
PA R :
2 0 0 2
S E Q . 0 2
Rated current
0000011.8
0000019.0
+
A
+11.8
Def:
T-
EN
LOC
ILim
n:0
AL
T+
E
PA R :
2 0 0 4
S E Q . 0 3
Rated speed
000001450
000000720
+
rpm
+1450
Def:
T-
EN
LOC
ILim
n:0
AL
T+
E
PA R :
2 0 0 8
S E Q . 0 5
Pole pairs
000000002
000000004
+
+2
Def:
T-
EN
LOC
ILim
n:0
AL
T+
E
PA R :
2 0 1 0
S E Q . 0 6
Rated power
000005.50
000007.36
+
kW
+5.50
Def:
T-
EN
LOC
ILim
n:0
AL
PA R :
2 0 0 0
E
V
+400
T-
EN
LOC
ILim
n:0
AL
PA R :
2 0 0 2
E
A
+11.8
T-
EN
LOC
ILim
n:0
AL
PA R :
2 0 0 4
E
rpm
+1450
T-
EN
LOC
ILim
n:0
AL
PA R :
2 0 0 8
E
+2
T-
EN
LOC
ILim
n:0
AL
PA R :
2 0 1 0
E
kW
+5.50
81