Chapter 2: Rack Mounting Preparation; Technical Specifications - Avaya Scopia Elite 6000 MCU Series Rack Mounting Manual

Table of Contents

Advertisement

Chapter 2: Rack mounting preparation

Technical specifications

This section details the system specifications of the MCU you purchased. Refer to this data when
preparing system setup and afterwards as a means of verifying that the environment still complies
with these requirements.
Hardware requirements
The following table refers to the physical details of the device:
Table 1: Physical device specifications
System power requirements
Input
AC Input
Maximum power consumption at
35°C
Environmental requirements
Operating temperature
Relative humidity
Storage and transit temperature
Acoustics
Physical requirements
Dimensions
January 2017
Scopia Elite MCU 6105, 6110 and
6120
100-240 VAC, 50/60 Hz
600W output @ 100-240V, 7.5A,
50-60Hz
200W, 250VA (682 BTU/h)
-40°C to 70°C (-40°F to 158°F), ambient
Width: 437mm (17.2"); height:
43mm (1.7"); depth 664mm (26.1")
Rack Mounting Guide for Avaya Scopia Elite 6000 MCU
Comments on this document? infodev@avaya.com
Scopia Elite MCU 6140
100-240 VAC, 50/60 Hz with hot-
swap redundant AC power supply
and feed (optional)
1000W output @ 100-120V,
12-10A, 50-60Hz
1200W output @ 120-140V,
12-10A, 50-60Hz
1800W output @ 200-240V,
10-8.5A, 50-60Hz
360W, 450VA (1228 BTU/h)
10°C to 35°C (50°F to 95°F)
5% to 90% non-condensing
Low noise fan speed control
Width: 437mm (17.2"); height:
43mm (1.7"); depth: 790mm
(31.1")
Table continues...