Beckhoff EP3356-0022 Documentation page 110

1-channel precise load cell analysis resistor bridge, 24 bit
Hide thumbs Also See for EP3356-0022:
Table of Contents

Advertisement

Commissioning/Configuration
Index 1C32 SM output parameter
Index (hex) Name
1C32:0
SM output parameter
1C32:01
Sync mode
1C32:02
Cycle time
1C32:03
Shift time
1C32:04
Sync modes supported
1C32:05
Minimum cycle time
1C32:06
Calc and copy time
1C32:07
Minimum delay time
1C32:08
Command
1C32:09
Maximum Delay time
1C32:0B
SM event missed counter
1C32:0C
Cycle exceeded counter
1C32:0D
Shift too short counter
1C32:20
Sync error
110
Meaning
Synchronization parameter of the outputs
Actual synchronization mode:
• 0: Free Run
• 1: Synchron with SM 3 Event (no Outputs
available)
• 2: DC - Synchron with SYNC0 Event
• 3: DC - Synchron with SYNC1 Event
Cycle time (in ns):
• Free Run: cycle time of the local timer
• Synchron with SM 2 Event: Cycle time of
the master
• DC-Mode: SYNC0/SYNC1 Cycle time
Time between SYNC0-Event and Input Latch (in
ns, only in DC-Mode)
Supported synchronization modes:
• Bit 0 = 1: Free Run is supported
• Bit 1 = 1: Synchron with SM 2 Event is
supported
• Bit 2-3 = 01: DC-Mode is supported
• Bit 4-5 = 01: Input Shift with local event
(Outputs available)
• Bit 4-5 = 10: Output Shift with SYNC1
Event (only DC mode)
• Bit 14 = 1: dynamic times (could be
measured  by writing 0x1C32:08)
Minimum cycle time supported (in ns)
Minimum time between SYNC0 and SYNC1
event (in ns, only DC mode)
• 0: Measurement of the times will be
stopped
• 1: Measurement of the times will be
started
The Entries 0x1C32:03, 0x1C32:05, 0x1C32:06,
0x1C32:09, 0x1C33:03 [} 111], 0x1C33:06 [} 111],
0x1C33:09 [} 111] will be updated with the maxi-
mum measured values.
The measured valued well be reset, if measured
again
Time between SYNC1-Event and output latch (in
ns, only in DC mode)
Number of the missed SM-Events in state OPER-
ATIONAL (only in DC Mode)
Number of the exceeded cycles in state OPERA-
TIONAL
Number of the too short distances between
SYNC0 and SYNC1 Event (only in DC Mode)
TRUE: In the last cycle the synchronization was
not correct (only in DC-Mode)
Version: 1.1.0
Data type
Flags
Default
UINT8
RO
0x20 (32
UINT16
RW
0x0001 (1
UINT32
RW
0x000C65D4
(812500
UINT32
RO
0x00000000
(0
)
dec
UINT16
RO
0xC007
(49159
UINT32
RO
0x0000C350
(50000
UINT32
RO
0x00000000
(0
)
dec
UINT32
RO
0x00000000
(0
)
dec
UINT16
RW
0x0000 (0
UINT32
RO
0x00000000
(0
)
dec
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
BOOLEAN
RO
0x00 (0
EP3356-0022
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec

Advertisement