Beckhoff EP3356-0022 Documentation page 104

1-channel precise load cell analysis resistor bridge, 24 bit
Hide thumbs Also See for EP3356-0022:
Table of Contents

Advertisement

Commissioning/Configuration
Information-/diagnostic data, Index 801E, 802E AI Internal data
Index (hex) Name
801E:0
AI Internal data
801E:01
ADC raw value 1
Index 9000 RMB Info data
Index (hex) Name
9000:0
RMB Info data
9000:11
mV/V
Index A000 RMB Diag data
Index (hex) Name
A000:0
RMB Diag data
A000:11
No internal referecnce supply No internal reference voltage at ADC input (U
A000:12
No internal referecnce bridge No internal reference voltage at ADC input  (U
A000:13
No external reference supply The external reference voltage is below ±1 V
A000:15
Overrange bridge
A000:16
Underrange bridge
A000:17
Overrange supply
A000:18
Underrange supply
Vendor configuration data, Index 801F, 802F AI Vendor data
Index (hex) Name
801F:0
AI Vendor data
801F:01
Calibration offset
801F:02
Calibration gain
Standard objects, Index 1000 Device type
Index (hex) Name
1000:0
Device type
Index 1008 Device name
Index (hex) Name
1008:0
Device name
Index 1009 Hardware version
Index (hex) Name
1009:0
Hardware version
Index 100A Software version
Index (hex) Name
100A:0
Software version
104
Meaning
Max. subindex
ADC raw value
Meaning
Max. subindex
Current mV/V value
Meaning
Max. subindex
channel)
channel
Overranged measuring value in the bridge sec-
tion
Underranged measuring value in the bridge sec-
tion
Overranged measuring value of the reference
voltage
Underranged measuring value of the reference
voltage
Meaning
Max. subindex
Offset (vendor calibration))
Gain (vendor calibration))
Meaning
Device type of the EtherCAT slave: The low word
contains the CoE profile used (5001). The high
word contains the module profile according to the
modular device profile.
Meaning
Device name of the EtherCAT slave
Meaning
Hardware version of the EtherCAT slave
Meaning
Firmware version of the EtherCAT slave
Version: 1.1.0
Data type
Flags
Default
UINT8
RO
0x01 (1
INT32
RO
0x00000000
(0
Data type
Flags
Default
UINT8
RO
0x11 (17
REAL32
RO
0x00000000
(0
Data type
Flags
Default
UINT8
RO
0x18 (24
BOOLEAN
RO
0x00 (0
Ref
BOOLEAN
RO
0x00 (0
Dif
BOOLEAN
RO
0x00 (0
BOOLEAN
RO
0x00 (0
BOOLEAN
RO
0x00 (0
BOOLEAN
RO
0x00 (0
BOOLEAN
RO
0x00 (0
Data type
Flags
Default
UINT8
RO
0x02 (2
INT32
RW
0x01E10000
(31522816
INT16
RW
0x4000
(16384
Data type
Flags
Default
UINT32
RO
0x01681389
(23597961
Data type
Flags
Default
STRING
RO
EL3356 /
EP3356
Data type
Flags
Default
STRING
RO
00
Data type
Flags
Default
STRING
RO
01
EP3356-0022
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec

Advertisement

Table of Contents
loading