Beckhoff EP3356-0022 Documentation page 101

1-channel precise load cell analysis resistor bridge, 24 bit
Hide thumbs Also See for EP3356-0022:
Table of Contents

Advertisement

Index (hex) Name
8000:23
Rated output
8000:24
Nominal load
8000:25
Zero balance
8000:26
Gravity of earth
8000:27
Scale factor
8000:28
Reference load
8000:29
Steady state window
8000:2A
Steady state tolerance
8000:31
Calibration interval
8000:32
Test interval
EP3356-0022
Meaning
Nominal sensitivity of sensor element in mV/V
Nominal load of force transducer/load cell/etc.
(e.g. in kg or N, ....)
Zero point offset in mV/V
Current gravity of earth (default 9.806650)
This factor is for rescaling of the process data,
e.g. for changing the indication from "kg" to "g",
you shall enter the factor "1000" here.
Reference weight for manual calibration
Time constant for the "steady state" bit (Idling
recognition [} 77])
Tolerance window for the "steady state" bit
Calibration interval for the automatic calibration of
the terminal/box (unit: 100 ms)
The automatic calibration can be prevented by
setting the process data bit "Disable calibration"
This object contains the testing interval for the
cyclic self test of the terminal/box
This interval is always a multiple (default: 10
the calibration interval (0x8000:31So the delivery
state of the testing interval result from 10 x 180 s
= 1800 s.
The self test can be prevented by setting the
process data bit "Disable calibration"
Version: 1.1.0
Commissioning/Configuration
Data type
Flags
Default
REAL32
RW
0x40000000
(1073741824
  = 2.0
REAL32
RW
0x40A00000
(1084227584
= 5.0
REAL32
RW
0x00000000
(0
REAL32
RW
0x411CE80A
(1092413450
= 9.806650
REAL32
RW
0x447A0000
(1148846080
= 1000.0
REAL32
RW
0x40A00000
(1084227584
= 5.0
UINT16
RW
0x03E8
(1000
UINT32
RW
0x00000005
(5
UINT16
RW
0x0708
(1800
UINT16
RW
0x000A (10
) of
dec
)
dec
)
dec
) = 0.0
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
101