SIS Configuration
and Control
The XTP R HWP 201 can be configured and controlled using Extron Simple Instruction
Set (SIS) commands or the XTP System Configuration Software (see
Configuration Software
details and SIS commands and responses when connected directly to the XTP R HWP 201.
Topics in this section include:
•
•
•
Host Device Connection
Use a connected computer running the Extron DataViewer utility to send and receive
SIS commands and responses. To connect directly to an XTP R HWP 201, connect the
computer to the XTP R HWP 201 through the front panel USB configuration port (see
figure
SIS Overview
Host-to-Device and Device-to-Host Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the XTP R HWP 201 determines that
a command is valid, it executes the command and sends a response to the host device. All
responses from the switcher to the host end with a carriage return and a line feed
(CR/LF =
more characters.
Error Responses
When the XTP R HWP 201 receives an SIS command and determines that it is valid, it
performs the command and sends the corresponding response to the host device. If the
command is determined invalid or contains invalid parameters, the receiver returns an error
response to the host. The error response codes are:
E10
E13
E14
E17
E22
on page 24). This section contains basic SIS communication
Host Device Connection
SIS Overview
Command and Response Tables for SIS Commands
8,
on page 10).
E
]
), which signals the end of the response character string. A string is one or
= Invalid command
= Invalid parameter
= Not valid for this configuration
= Invalid command for signal type
= Busy
XTP R HWP 201 Wallplate Receiver • SIS Configuration and Control
XTP System
20