E
MENU and ENTER buttons (see
display menu system.
F
Navigation buttons — Press these buttons to navigate through the on-screen display menu system or change settings.
Reset
Press the rear panel recessed reset button (see figure 1,
or the unit gets disconnected during the update process. The different resets allow the device to revert to the factory loaded
firmware, reset IP seetings, or reset configuration to default (see the Reset Modes table, for details on the reset modes).
Mode Activation
Hold in the recessed rear panel
Reset button while applying power
to the unit.
NOTE:
Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the most current
firmware to the device.
Hold in the Reset button about
6 seconds until the Power LED
blinks twice. Then, release and
press the Reset button momentarily
(<1 second) again within 1 second*.
Hold in the Reset button until the
Power LED blinks three times (once
at 3 seconds, again at 6 seconds,
again at 9 seconds). Then, release
and press the Reset button again
within 1 second*.
NOTES:
*For these modes, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this device have been set to the device serial number. In the
event of a complete system reset, the passwords convert to the default, which is

Front Panel Lockout Mode (Executive Mode)

The front panel lockout mode limits operation of the device from the front panel. When enabled, use SIS commands or the
Product Configuration Software (PCS) to configure the device. To enable or disable the front panel lockout mode through the front
panel, press and hold the MENU (see figure 6,
LED blinks.

Configuration and Control

To configure the FOX3 SR, use the front panel controls and the on-screen display (OSD) menu, Simple instruction Set (SIS)
commands, or PCS.
4
figure 6
on page 3)— Press these buttons to access and navigate the on-screen
K
on page 1) if the FOX3 scaling receiver firmware is corrupted
Reset Modes
Result
The unit reverts to the factory default
firmware for a single power cycle.
Sets the following back to factory
default:
Port mapping
IP address: 192.168.254.254
Subnet mask address:
255.255.255.0
Gateway address: 0.0.0.0
Turns DHCP off.
Power LED blinks 4 times during reset.
plete reset to factory defaults
A com
(except the firmwa
re).
thing mode 4 does.
Does every
Clears port configurations.
Resets all IP options.
Clears all user settings.
Clears all files from the unit.
The Power LED blinks four times.
E
F
) and down arrow (
Purpose and Notes
Use to revert to the factory default
firmware for a single power cycle if
incompatibility issues arise with user-
loaded firmware. All user files and
settings are maintained.
Use to reset all IP settings back to the
factory defaults.
Equivalent to SIS command 1ZQQQ.
Use to start over with default
configuration and uploading, and also
to replace events.
Equivalent to SIS command ZQQQ.
extron
.
) buttons simultaneously for 5 seconds or until the power

Advertisement