Hydraulic Alarms; Bin Sequencing Alarms; Chain Oiler Alarms - New Leader AGCO NL5258G5 Operator's Manual

Hopper type spreaders
Table of Contents

Advertisement

Controller Operations
Header

Hydraulic Alarms

Alarm
Conveyor
Hydraulic
"Conveyor Hydraulic Pressure Exceeds
Pressure Exceeds
Maximum
System Hydraulic
"System Hydraulic Pressure Exceeds
Pressure Exceeds
Maximum
Hydraulic Fluid
Level Low
Hydraulic Fluid
"Hydraulic Fluid Temperature Below
Temperature
Below Minimum
Hydraulic Fluid
Temperature
"Hydraulic Fluid Temperature Exceeds
Exceeds
Maximum
Hydraulic Filter
Restriction
"Hydraulic Filter Restriction Detected."
Detected

Bin Sequencing Alarms

Alarm
Container
Advance
End of Sequence

Chain Oiler Alarms

Alarm
Manually disable or shut off the spinner
Disable Spinners
Return the spinner hydraulic circuit to a
Enable Spinners
Conveyor
Lubrication
Conveyor Chain Lubrication Is Required.
Required
www.New-Leader.com
(800) 363-1771
Description
Maximum Operating Range."
Maximum Operating Range."
"Hydraulic Fluid Level Low."
Minimum Operating Range."
Maximum Operating Range."
Description
Moving to next container in the
sequence.
End of container sequence, do you
wish to start the sequence from the
beginning?
Description
hydraulic circuit.
fi eld ready condition.
Conveyor hydraulic pressure exceeds
[Max Conveyor Hydraulics Pressure]
setting for a period of fi ve consecutive
seconds or longer.
System hydraulic pressure exceeds [Max
System Hydraulics Pressure] setting for
a period of fi ve consecutive seconds or
longer.
Hydraulic fl uid level has fallen below
lowest level tank sensor.
Hydraulic temperature is below 65°F
(18°C). Hydraulic fl uid too cold to
operate machine.
Hydraulic temperature exceeds
maximum operating range, greater than
or equal to 200°F (93°C).
Hydraulic fi lter pressure is greater than
or equal to 25 psi for fi ve consecutive
seconds or longer.
At the point when the [Container
Advance] criteria has been met.
At the point the last container in the
sequence has met the [Container
Advance] criteria.
The point the user selects to run the
chain oiler routine.
The point the user exits the chain oiler
routine.
[Service Reminder On] setting is enabled
and [Service Reminder Interval] has
expired.
- 125 -
NL5258G5/NL5300G5
Trigger
Trigger
Trigger
314732-AA-B