Controller Operations
Header
Spinner Alarms
Alarm
CLF Basic Single
Spinners Not
Responding
CLF Basic
Independent
"Spinner Not Responding" + [Spinner
Spinners Not
Responding
Spinners Off
Spinners On
314732-AA-B
Description
"Spinners Not Responding"
Name]
"Stop Application, Spinners Off!"
"Turn spinner switch off to prevent
spinners from running!"
Automatic control for spinners must
be enabled. [CLF Mode] [Basic Single]
must be selected. At least one product
bin must be commanded on. Perceived
spinner speed is greater than 30 rpm in
error from [Target Spinner Speed] for a
period of fi ve consecutive seconds or
longer.
enabled. [CLF Mode] [Basic
Independent] must be selected. At least
one product bin must be commanded
on. Perceived spinner speed is greater
than 30 rpm in error from [Target Spinner
Speed] for a period of fi ve consecutive
seconds or longer.
CLF is enabled, no spinner speed
detected, one or more control channels
is commanded on.
Upon system start up, [CLF Mode]
enabled, spinner functionality switch
detected in the ON position.