Deleting Variable Names from the Watch Tab Page
Right-click the variable name to delete in the Watch Tab Page and select Delete from the menu. Or,
press the Delete Key to delete the variable name directly.
The variable name and the row it was displayed on are deleted.
8-6-5
Controlling BOOL Variables, Changing Present Values, and
Using Forced Refreshing
You can debug the safety program by controlling BOOL variables (Set/Reset), changing present val-
ues, and executing forced refreshing from the Sysmac Studio.
Make sure that the area around the system is safe before you control BOOL variables
(Set/Reset), change present values, and execute forced refreshing.
The outputs may operate and may cause serious injury.
Controlling BOOL Variables (Set/Reset)
This function allows you to change the values of BOOL variables in the FBD editor or Watch Tab Page
to debug safety programs.
 Controlling BOOL Variables in the FBD Editor (Set/Reset)
1
Click the present value for the BOOL variable to change.
Example: To set variable a, click the present value of FALSE.
Click here.
The value changes to a temporary status.
A light blue triangle is displayed at the lower left of the value. This indicates that a temporary
TRUE/FALSE value is in effect.
A light blue triangle is displayed.
Each click toggles the temporary value through Present Value − TRUE − FALSE − Present
Value.
NX-series Safety Control Unit User's Manual (Z930)
8 Checking Operation and Actual Operation
WARNING
8
8 - 33