Omron NX-SID Series User Manual page 411

Machine automation controller
Hide thumbs Also See for NX-SID Series:
Table of Contents

Advertisement

Objects That Accept I/O Allocations
These objects accept I/O allocations.
You cannot access the objects with the Read NX Unit Object instruction or the Write NX Unit Object
instruction.
Refer to the NJ/NX-series Instructions Reference Manual (Cat. No. W502) for details on the Read NX
Unit Object instruction or the Write NX Unit Object instruction.
Sub-
Index
index
Object name
(hex)
(hex)
6000
---
FSoE Slave Frame Ele-
ments
00
Number of Entries
01
FSoE Slave CMD
02
FSoE Slave Conn_ID
03
FSoE Slave CRC_0
6001
---
Safety Input Data
00
Number of Entries
01
Safety Input 1st Byte
6002
---
Standard Input Data
00
Number of Entries
01
Standard Input 1st Byte
02
Standard Input 2nd Byte
*1. The details of the Standard Input 1st Byte are as follows:
Bit 0: Si00 Logical Value
Bit 1: Si01 Logical Value
Bit 2: Si02 Logical Value
Bit 3: Si03 Logical Value
Bit 4: Safety Connection Status
Bit 5: Safety Input Terminal Status
Bit 6: Unit Normal Status
Bit 7: IO Power Supply Error Flag
*2. The details of the Standard Input 2nd Byte are as follows:
Bit 0: Si00 Status
Bit 1: Si01 Status
Bit 2: Si02 Status
Bit 3: Si03 Status
Bits 4 to 7: Reserved
NX-series Safety Control Unit User's Manual (Z930)
Default
Data range
value
---
---
3
3
00 hex
00 to FF hex
0000 hex
0000 to FFFF hex
0000 hex
0000 to FFFF hex
---
---
1
1
00 hex
00 to FF hex
---
---
2
2
00 hex
*1
00 to FF hex
00 hex
*2
00 to FF hex
Data
Acc
I/O allo-
Unit
type
ess
cation
---
---
---
---
---
USINT
RO
Not pos-
sible.
---
BYTE
RO
Possi-
ble.
---
WORD
RO
Possi-
ble.
---
WORD
RO
Possi-
ble.
---
---
---
---
---
USINT
RO
Not pos-
sible.
---
BYTE
RO
Possi-
ble.
---
---
---
---
---
USINT
RO
Not pos-
sible.
---
BYTE
RO
Possi-
ble.
---
BYTE
RO
Possi-
ble.
Appendix
Data
attri-
bute
---
A
---
---
---
---
---
---
---
---
---
---
---
A - 11

Hide quick links:

Advertisement

Table of Contents
loading