• Functions Supported for Unit Version 3.0 or Later
CS1-H CPU Units
Function blocks
Serial Gateway (converting FINS commands to CompoWay/F
commands at the built-in serial port)
Comment memory (in internal flash memory)
Expanded simple backup data
New application
TXDU(256), RXDU(255) (support no-protocol
instructions
communications with Serial Communications
Units with unit version 1.2 or later)
Model conversion instructions: XFERC(565),
DISTC(566), COLLC(567), MOVBC(568),
BCNTC(621)
Special function block instructions: GETID(286)
Additional
TXD(235) and RXD(236) instructions (support
instruction func-
no-protocol communications with Serial Commu-
tions
nications Boards with unit version 1.2 or later)
CS1D CPU Units
CJ1-H/CJ1M CPU Units
Function blocks
Serial Gateway (converting FINS commands to CompoWay/F
commands at the built-in serial port)
Comment memory (in internal flash memory)
Expanded simple backup data
New application
TXDU(256), RXDU(255) (support no-protocol
instructions
communications with Serial Communications
Units with unit version 1.2 or later)
Model conversion instructions: XFERC(565),
DISTC(566), COLLC(567), MOVBC(568),
BCNTC(621)
Special function block instructions: GETID(286)
Additional
PRV(881) and PRV2(883) instructions: Added
instruction func-
high-frequency calculation methods for calculat-
tions
ing pulse frequency. (CJ1M CPU Units only)
xiii
CX-Programmer 5.0 or higher must be used to enable using the functions
added for unit version 3.0.
Function
Unit version 3.0 is not supported.
Function
User programs that contain functions supported only by CPU Units with unit
version 3.0 or later cannot be used on CS/CJ-series CPU Units with unit ver-
sion 2.0 or earlier. An error message will be displayed if an attempt is made to
download programs containing unit version 3.0 functions to a CPU Unit with a
unit version of 2.0 or earlier, and the download will not be possible.
If an object program file (.OBJ) using these functions is transferred to a CPU
Unit with a unit version of 2.0 or earlier, a program error will occur when oper-
ation is started or when the unit version 3.0 function is executed, and CPU
Unit operation will stop.
CS1@-CPU@@H
Unit version 3.0 or
Other unit versions
later
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
CJ1H-CPU@@H-R, CJ1@-CPU@@H,
CJ1G-CPU@@P, CJ1M-CPU@@
Unit version 3.0 or
Other unit versions
later
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
OK
---
CS/CJ/NSJ Series Instructions Reference Manual (W474)