Omron SYSMAC CS Series Instruction & Reference Manual page 834

Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

3. Instructions
 Start Code/End Code Settings and Send Data
ST
1, 2, 3, 4, 5, 6...
ST
1, 2, 3, 4, 5, 6...
ST
Serial port on Serial Communications Unit
800
No Start or End Code
1, 2, 3, 4, 5, 6...
Only Start Code
1, 2, 3, 4, 5, 6...
Only End Code
ED
Start and End Code
1, 2, 3, 4, 5, 6...
ED
CR+LF End Code
LF
CR
Start and CR+LF End Code
1, 2, 3, 4, 5, 6...
CR LF
Data received.
Bytes
1
2
3
N
Storage order
4
(256 bytes max.)
5
6
Number of bytes
(Specified in allocated
DM Setup Area)
Number of bytes
(Specified in allocated
DM Setup Area)
Number of bytes up to ED:
256 max.
Number of bytes between
ST and ED: 256 max.
Number of bytes up to
CR+LF: 256 max.
Number of bytes between
ST and CR+LF: 256 max.
Byte order
0: Most significant bytes first
Most signifi-
Least signif-
cant bytes
icant bytes
15
8
7
1
2
D
3
4
D+1
5
6
D+2
Byte order
1: Least significant bytes first
Most signifi-
Least signif-
cant bytes
icant bytes
15
8
7
2
1
D
4
3
D+1
6
5
D+2
CS/CJ/NSJ Series Instructions Reference Manual (W474)