PRV
Instruction
Mnemonic
HIGH-SPEED
PRV
COUNTER PV READ
Symbol
Applicable Program Areas
Function block
Area
definitions
Usage
OK
Operands
Operand
P
Port specifier
C
Control data
D
First destination word
P: Port Specifier
P
0000 hex
Pulse output 0
0001 hex
Pulse output 1
0002 hex
Pulse output 2 (CJ2M only)
0003 hex
Pulse output 3 (CJ2M only)
0010 hex
High-speed counter 0
0011 hex
High-speed counter 1
0012 hex
High-speed counter 2 (CJ2M only)
0013 hex
High-speed counter 3 (CJ2M only)
0100 hex
Interrupt input 0 in counter mode
0101 hex
Interrupt input 1 in counter mode
0102 hex
Interrupt input 2 in counter mode
0103 hex
Interrupt input 3 in counter mode
0104 hex
Input interrupt 4 in counter mode (CJ2M only)
0105 hex
Input interrupt 5 in counter mode (CJ2M only)
0106 hex
Input interrupt 6 in counter mode (CJ2M only)
0107 hex
Input interrupt 7 in counter mode (CJ2M only)
1000 hex
PWM(891) output 0
1001 hex
PWM(891) output 1
1002 hex
PWM output 2 (CJ2M only)
1003 hex
PWM output 3 (CJ2M only)
CS/CJ/NSJ Series Instructions Reference Manual (W474)
Function
Variations
code
@PRV
881
Block program areas
Step program areas
OK
OK
Description
Function
PRV(881) reads the High-speed counter PV and pulse output PV
and interrupt input PV in counter mode.
PRV
PRV(881)
P: Port specifier
P
C: Control data
C
D
D: First destination word
Subroutines
Interrupt tasks
OK
Port
3. Instructions
SFC action or transition
programs
OK
OK
Data type
Size
---
1
---
1
WORD
Variable
653
3

Advertisement