PRICES
This function is active only if the machine has a
payment module.
From this menu it is possible to set the prices individually
(for each selection) or globally (the same price for all the
selections) and define the intervals of the promotional
band.
The machine can manage up to 4 different prices for
each selection, which can be active depending on the
time band that has been set (standard or promotional)
and/or on the payment system used.
The prices are grouped in 4 lists and can be program-
med (from 0 to 65,535), for each of the 4 lists, both
globally with the same price for all the selections and
individually for each selection.
The price of each selection can be varied also directly
from the keyboard.
In the event that most of the products are sold at the
same price it is more convenient to program the price
globally and then change the price of the selections
which have a different sales price.
,
,
bDv
ExEcutivE
valiDators
With these systems, apart from the standard price list, it
is possible to manage a promotional price list if the time
band is enabled by means of the appropriate function.
The selections will be dispensed at the price of the pro-
motional list in all the set time intervals.
mDb
With these systems it is possible to establish whether to
use the 4 price lists at the same time or to use two bands
alternatively depending on the time band that has been
set.
If the time band is not used, apart from the standard price
list it is possible to manage three further price lists depen-
ding on the type of cashless support used (key 1-3).
If the time band is used, the selections will be dispen-
sed, for the cashless system, at a price which is different
from the standard price; during the time intervals which
have been programmed, the selections will be dispen-
sed with two different promotional prices for the standard
list and for the cashless system.
p
romotioNal timE baND
You can program 4 time intervals for different prices retail.
Intervals can be set for hours (from 00 Am to 11 Pm) and
for minutes (from 00 to 59).
To disable the time band, set the start and end times to 00.
The reference time is given by an internal clock which
can be adjusted from the configuration menu of the ma-
chine (see the "DA Configuration" paragraph ).
© by N&W GLOBAL VENDING S.p.A.
DOSES
This group of functions allows you to define all the varia-
bles which contribute to the preparation of the drink
s
ElEctioN paramEtErs
By confirming this function, you can access the subme-
nus for managing the parameters; the first option is the
choice of the selection which you would like to change.
By pressing a key on the keyboard, the corresponding
parameters will be displayed, which will be different if the
key is a selection or a preselection.
s
Et compositioN
This group of functions allows you to modify the doses
and the parameters in relation to water and powder of
the chosen drink.
By confirming this function, the list of ingredients
(powder/s and water) of the drink is shown, listed in the
order in which the water dose is dispensed (see doses
table).
A drink can be composed of a maximum of 4 ingredients
(powder/s and water).
Each dose of water can be matched to more than one
powder.
The dispensing of water can be controlled through the
following parameters:
m
ixEr
m
ixiNg moDE
It is possible, for each selection, to set the mixing dura-
tion of each dose of water which forms the selection.
The duration can be set in two different modes:
- absolute
which means independent of the solenoid valve ope-
ning time.
The value of the mixing duration is set in terms of relati-
ve volumetric counter pulses (CDV)
- relative
that is, by difference, more or less than the time of clo-
sing of the solenoid valve.
E.g.: if the value is 0, the mixing will stop exactly at the
same closing time of the solenoid valve.
The duration value of the mixing is always expressed in
tenths of a second.
m
(
/
ixiNg spEED
loW
mEDium
The mixing speed can be defined as a function of the
desired presentation of the product.
m
ixiNg timE
It is possible to define, within a single product, for how
long the mixer shall be active after the closure of the
solenoid valve.
30
/
)
HigH
09-2013 4485-00
Need help?
Do you have a question about the Krea and is the answer not in the manual?