D
EscalEr
The machine is supplied without descaler.
In the event that the machine is connected to very hard
water, it is necessary to install a descaler.
Use descalers with a capacity which is adequate to the
actual use of the machine.
In case the machine uses a water tank, it is possible to
use appropriate filtering cartridges.
The cartridges will need to be replaced periodically
depending on the water quality and the indications given
by the manufacturer.
The descalers, also available as an accessory, need to
be periodically regenerated or replaced according to the
manufacturer's instructions.

ELECTRICAL CONNECTION

The machine requires a single phase voltage of 120 V∿
and it is protected by a 15 A fuse.
For the connection, make sure that the plates data corre-
spond to the mains data, and in particular: The value of
the voltage shall be within the recommended limits;
it is mandatory to use a switch, in accordance with
current the installation standards, located in an ac-
cessible position, which has characteristics suita-
ble for supporting the maximum load and ensures
the complete disconnection from the power supply
under conditions of overvoltage category III and,
therefore, which protects the circuit against ground
faults, overloads and short circuits
The switch, the socket and the plug shall be placed in an
accessible position.
The electrical safety of the machine is ensured only
when the machine is correctly connected to an efficient
earthling system, as foreseen by the current safety regu-
lations.
It is necessary to verify this fundamental safety re-
quirement and, in case of doubt, request an accura-
te check of the system by qualified personnel.
The use of adapters, multiple plugs and/or exten-
sion cables is forbidden.
The manufacturer shall not be held responsible for
any damage caused by the non-observance of the
above-mentioned precautions.
© by N&W GLOBAL VENDING S.p.A.
l
iNE cablE rEplacEmENt
The power supply cable has a non-separable plug; The
replacement of the connection cable shall be carried
out only by qualified personnel and using only cables of
the type SJTW 14AWG /3C 105 °C BLACK with NEMA
5-15P certified plug.
To replace the cable, after disconnecting the device from
the power supply, it is necessary to open the hinged lid
and connect the new cable.
4
3
2
1
Fig. 16
1- Mains lead
2- Flip cover
3- Mains fuse
4- Water inlet
16