INDIVIDUAL PRICE

This function is active only if the machine has a
payment module.
The machine can manage up to 4 different prices for
each selection, which can be active depending on the
time band that has been set (standard or promotional)
and/or on the payment system used.
Through this function it is possible to vary the sales price
for each selection, selecting among the available price
bands.

MANAGEMENT OF THE COIN BOX TUBES

This function is active only if the machine has a
payment module.
By entering into this function it is possible to manually
load or empty the coin mech tubes.
By confirming the loading operation, the display shows
"Credit : ——" which is the amount of money in the tubes
available for being returned; if you introduce the coin in
the validator, the display will increase the amount of mo-
ney in the tubes which is available for being returned.
By confirming the emptying operation, it is possible to
establish on which of the tubes to intervene. Every time
the confirmation key is pressed � , a coin is ejected from
the active tube.

BOILER TEMPERATURE

This function allows you to read, directly in °C, the tem-
perature detected in the boiler.
TEST
For complete or partial dispensing tests, each button (or
combination of keys, depending on the models) activa-
tes the corresponding selection (see doses-selections
table).
Please note For the espresso-based selections,
with the partial dispensing of powder and water
only the additions are dispensed; if the selection
does not foresee additions, the display will show
"Selection Disabled"
The possible test dispensing are:
- Complete dispensing
- Dispensing of only water
- Dispensing of only powder
- Dispensing without accessories (without cup, stirrer
and sugar)
- Dispensing of accessories only (not available for this
model)
© by N&W GLOBAL VENDING S.p.A.

EVA DTS

EVA DTS communication protocol (European Vending
Associations Data Transfer System) allows the communi-
cation with statistics acquisition devices.
c
oNNEctioN
By activating this function, the machine waits for the con-
nection with a statistics activation device EVA DTS.
a
lErt couNtErs rEsEt
This function is used to reset all the counters which ma-
nage the "product running out" alerts.
Press the key � to reset.
p
artial rEsEt
This function allows you to reset the counter which ma-
nages the "product running out" alert of a single product.
Press the key � to reset.