Dsp 402 State Transitions - Danfoss MCA 123 POWERLINK Operating Instructions Manual

Table of Contents

Advertisement

How to Control the Frequenc...

5.5.3 DSP 402 State Transitions

Transition State
-
Start condition
0
Start-up⇒Not ready to switch on
1
Switch On Disabled⇒Switch On Disabled
2
Not Ready to Switch On⇒Switched On
3
Ready to Switch On⇒Switched On
4
Switched On⇒Ready to Switch On
5
Operation Enabled⇒Switched On
6
Switched On⇒Ready to Switch On
7
Ready to Switch On⇒Switch On Disable
8
Operation Enable⇒Ready to Switch On
5
5
9
Operation Enable⇒Switch On Disable
10
Switched On⇒Switched On Disable
11
Operation Enabled⇒Quick Stop Active
11
Operation Enabled⇒Quick Stop Active
12
Quick Stop Active⇒Switch On Disabled
13
All states⇒Fault Reaction Active
14
Fault Reaction Active⇒Fault
15
Fault⇒Switch On Disabled
16
Quick Stop Active⇒Operation Enable (not
supported)
Table 5.12 DSP 402 State Transitions
22
MCA 123 POWERLINK Operating Instructions
Control word Status word Action
0000
0000
0000
0200
0000, 0001
0240
0006
0231
0007
0233
000F
0237
0007
0233
0006
0231
0001, 0000
0240
0006
0231
0001, 0000
0240
0001, 0000
0240
0002
0207
0003
0217
0001, 0000
0240
xxxx
023F
xxxx
023F
0000
0240
-
-
®
MG92C102 - VLT
is a registered Danfoss trademark
-
-
-
-
-
-
Motor ramps to 0 RPM with programmed ramp
down parameter.
-
-
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
Motor ramps to 0 RPM with programmed quick
ramp parameter.
Motor ramps to 0 RPM with programmed quick
ramp parameter.
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
-
-
-
-