Troubleshooting; Resolving Safe-State Mode By Soft Reset - Danfoss PVED-CLS Startup Manual

Hide thumbs Also See for PVED-CLS:
Table of Contents

Advertisement

Application Guide
PVED-CLS startup guide

Troubleshooting

Resolving safe-state mode by soft reset

©
Danfoss | October 2018
If the PVED-CLS is in safe-state mode, it is possible that a soft reset will resolve the underlying issue.
1. Open the Mode switch page.
The Mode Switch page is used to change between Bootloader and Application modes. When a
Config page is entered while in Normal View in the Service Tool, the PVED-CLS enters Bootloader
mode. To return to Application mode go to the Mode switch page and press the "Go to application"
button.
If the PVED-CLS is already in application mode (there is no red or yellow box around the Main and
Safety states) the "Go to application" button does not need to be pressed.
2. Press the "Soft Reset" button to reboot the PVED-CLS.
This may clear the Safe State if it was caused by exceeding a speed threshold or a temporarily missing
message.
If the PVED-CLS remains in safe-state mode, proceed to the
codes
on page 42 section for further troubleshooting.
Resolving safe-state mode with SPN and FMI
AB285975085591en-000101 | 41