7.3 POWERLINK - Specific Parameter List

Parameter
8-01 Control Site
8-02 Control Word Source
8-03 Control Word Timeout Time
8-04 Control Word Timeout Function
8-05 End-of-Timeout Function
8-06 Reset Control Word Timeout
8-07 Diagnosis Trigger
8-10 Control Word Profile
8-13 Configurable Status Word STW
8-50 Coasting Select
8-51 Quick Stop Select
8-52 DC Brake Select
8-53 Start Select
8-54 Reversing Select
8-55 Set-up Select
8-56 Preset Reference Select
7
7
8-90 Bus Jog 1 Speed
8-91 Bus Jog 2 Speed
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
12-08 Host Name
12-09 Physical Address
12-10 Link Status
12-11 Link Duration
12-12 Auto Negotiation
12-13 Link Speed
12-14 Link Duplex
12-20 Control Instance
12-21 Process Data Config Write
12-22 Process Data Config Read
12-23 Process Data Config Write Size
12-24 Process Data Config Read Size
12-28 Store Data Values
12-29 Store Always
12-60 Node ID
12-80 FTP Server
12-81 HTTP Server
12-82 SMTP Service
12-89 Transparent Socket Channel Port
12-90 Cable Diagnostic
12-91 Auto Cross Over
12-93 Cable Error Length
12-98 Interface Counters
12-99 Media Counters
16-84 Comm. Option STW
16-90 Alarm Word
40
MCA 123 POWERLINK Operating Instructions
Default value
Range
[0] Dig. & ctrl. word
[0-2]
[0] FC RS485
[0-4]
1
0.1-18000
[0] Off
[0-10]
[0] Hold set-up
[0-1]
[0] Do not reset
[0-1]
[0] Disable
[0-3]
[0] FC profile
[0-x]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
[3] *Logic OR
[0-3]
0-4-13 Motor Speed
100 rpm
High Limit [RPM]
0-4-13 Motor Speed
200 rpm
High Limit [RPM]
[20] *From node ID
-
192.168.100.xxx
-
255.255.255.0
-
0.0.0.0
-
-
00:1B:08:00:00:00
-
[0] No Link
[0-1]
00:00:00:00
-
[1] On
[0-1]
[0] None
[0-2]
[1] Full Duplex
[0-1]
Application Dependent
0-255
Application Dependent
16
16
0
0-4294967295
[0] Off
[0]
[0-240]
[0] Disable
[0–1]
[0] Disable
[0–1]
[0] Disable
[0–1]
[0] Disable
[0–1]
[0] Disable
[0-1]
[0] Enable
[0-1]
0
0-200
0
0-65535
0
0-65535
0
0-FFFF
0
0-FFFF
®
MG92C102 - VLT
is a registered Danfoss trademark
Conversion index
Data type
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
67
Uint16
67
Uint16
-
Unsigned 8
-
Unsigned 32
-
Unsigned 32
-
Unsigned 32
-
String
-
Visible string 17
-
Unsigned 8
-
Time diff. w/date
-
Unsigned 8
-
Unsigned 8
-
Unsigned 8[
1-32
1-32
Unsigned 8
-
Unsigned 8
-
Unsigned 8
-
Unsigned 8
-
Unsigned 8
-
Unsigned 8
-
Unsigned 8
0
Unsigned 16
-
Unsigned 16
-
Unsigned 16
0
V2
0
Uint32