1.6.3.14 CFM
By default, a maintenance domain level value of 4 will be used; if you wish, you can change this value to
lower or higher level if you like from 0 to 7. For this configuration example, we will provision a unique
Maintenance End Point ID for each VSP 7000 switch.
Switch
CFM
7001, 7002, 7003, 7004
7001
7002
7003
7004
Enable CFM
7001(config)#cfm spbm mepid 7001
7001(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7002(config)#cfm spbm mepid 7002
7002(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7003(config)#cfm spbm mepid 7003
7003(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7004(config)#cfm spbm mepid 7004
7004(config)#cfm spbm enable
--------------------------------------------------------------------------------------
Verify Operations
7001#l2ping vlan <4051 | 4052> <routernodename | mac> <SPB node name>
7001#l2tracerotue <4051 | 4052> <mac | routernodename> <SPB node name>
August 2015
Parameter
CFM
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
Avaya Inc. – External Distribution
avaya.com
Value
Enabled
7001
7002
7003
7004
92