VLAN – Change configuration control to automatic
7001(config)#vlan configcontrol automatic
SPBM Configuration
7001(config)#vlan create 4051 name BVLAN-1 type spbm-bvlan
7001(config)#vlan create 4052 name BVLAN-2 type spbm-bvlan
7001(config)#spbm
7001(config)#router isis
7001(config-isis)#spbm 1
7001(config-isis)#spbm 1 b-vid 4051-4052 primary 4051
7001(config-isis)#spbm 1 nick-name 0.70.01
7001(config-isis)#manual-area 49.0001
7001(config-isis)#sys-name 7001
7001(config-isis)#spbm 1 smlt-peer-system-id 3cb1.5bff.5fdf
7001(config-isis)#exit
7001(config)#router isis enable
--------------------------------------------------------------------------------------
For switches 7002, 7003, and 7004, use the same configuration as above except for the
items shown below
--------------------------------------------------------------------------------------
7002(config-isis)#spbm 1 nick-name 0.70.02
7002(config-isis)#sys-name 7002
7002(config-isis)#spbm 1 smlt-peer-system-id fca8.41f6.37df
--------------------------------------------------------------------------------------
7003(config-isis)#spbm 1 nick-name 0.70.03
7003(config-isis)#sys-name 7003
7003(config-isis)#spbm 1 smlt-peer-system-id 7030.1823.9865
--------------------------------------------------------------------------------------
7004(config-isis)#spbm 1 nick-name 0.70.04
7004(config-isis)#sys-name 7004
7003(config-isis)#spbm 1 smlt-peer-system-id 7030.1823.7c65
Enter the ALCI show isis system-id on each peer switch to get the System ID value for the spbm
1 smlt-peer-system-id xxxx.xxxx.xxxx command. Each switch in the cluster must peer with its
peer's System ID value.
August 2015
Avaya Inc. – External Distribution
avaya.com
80