Avaya VSP 7000 Technical Configuration Manual page 47

Resilient data center solutions
Hide thumbs Also See for VSP 7000:
Table of Contents

Advertisement

1.6.1.12 CFM
By default, a maintenance domain level value of 4 will be used; if you wish, you can change this value to
lower or higher level from 0 to 7. For this configuration example, we will provision a unique Maintenance
End Point ID for each VSP 7000 switch.
Switch
CFM
7001, 7002, 7003, 7004
7001
7002
7003
7004
Enable CFM
7001(config)#cfm spbm mepid 7001
7001(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7002(config)#cfm spbm mepid 7002
7002(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7003(config)#cfm spbm mepid 7003
7003(config)#cfm spbm enable
--------------------------------------------------------------------------------------
7004(config)#cfm spbm mepid 7004
7004(config)#cfm spbm enable
--------------------------------------------------------------------------------------
Verify Operations
7001#l2 ping vlan <4051 | 4052> <routernodename | mac> <SPB node name>
7001#l2tracerotue <4051 | 4052> <mac | routernodename> <SPB node name>
Example:
7001#l2ping vlan 4051 routernodename 7004
Please wait for l2ping to complete or press CTRL-C to abort
----70:30:18:23:98:65
1 packets transmitted, 1 packets received,
August 2015
Parameter
CFM
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
Maintenance End Point (MEP) ID
L2 PING Statistics----
0.00% packet loss
Avaya Inc. – External Distribution
Value
Enabled
7001
7002
7003
7004
0(64) bytes of data
avaya.com
47