Section 2 - Familiarization
Base Control Console
Enable Switch
Platform Lower/Neutral/
Raise Switch
Emergency Stop
Button
Emergency Lowering
Valve
2.4-2 Base Control Console
1. On engine control console, select
"
" start position to start the engine.
• Test Emergency Stop
1. Push in "
" emergency stop button.
Result: Engine should shut down and
aerial platform functions should not
operate.
2. Pull out "
" emergency stop button and
restart engine.
• Test Auxiliary Start Switch
1. On base control console, select and hold
enable switch and start engine using
auxiliary start switch.
Result: Engine should start.
2. Release enable switch.
Result: Engine should shut off.
3. Attempt to start engine without selecting
and holding enable switch.
Result: Engine should not start.
Mid Size & Full Size RTs
Engine Powered
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Model 71XX
Models 88XX & 9250
Auxiliary Start
Switch
contained in this operating manual and on the aerial platform.
Platform Lower/Neutral/
Raise Switch
Enable Switch
Emergency Stop
Button
• Test Base Lift Enable
1. Start the engine.
2. On base control console, select and hold
lower/neutral/raise switch "
position without selecting and holding
enable switch.
Result: Platform should not rise.
• Test Lower/Neutral/Raise Switch
1. On base control console, select and hold
enable switch and "
with lower/neutral/raise switch.
Result: Platform should rise.
2. Select and hold enable switch and fully
"
" lower the platform with lower/
neutral/raise switch.
Result: Platform should fully lower.