Start Operation
3.8-10

Hydraulic Outriggers (If Equipped)

These devices are mounted to the four corners of the
base.
3.8-10a

Before Operation

1.
Move around aerial platform to check overhead
clearances and ground obstructions.
2.
Lower the platform completely. Refer to
Section
3.8-4. Outrigger controls are not functional
when platform is raised.
3.
Check that the supporting surface under the
tires and outrigger pads is firm and capable of
supporting aerial platform and rated load. Do not
place outrigger pad on a street drain, manhole
cover or other unsupported surface.
3.8-10b

To Extend Outriggers

1.
On outrigger control console, select and hold
"
" enable switch to provide power to outrigger
circuit.
2.
Auto Extension: Select auto-level switch to
"
" extend position until leveling indicator light
stops flashing and remains on. Aerial platform
should be level and completely supported by the
outriggers.
Manual Extension: Select corresponding
outrigger extend/retract switch to "
position until platform is fully supported by
outriggers and is level. The indicator light flashes
while platform is being leveled and remains on
once platform is level.
The indicator light has the following states:
Off: The outriggers are fully retracted.
Flashing Rapidly: The outriggers are
extending or retracting.
Flashing: Not all outrigger legs have firm
ground contact or aerial platform is not
level.
On: The outriggers are extended and the
platform is level.
Page 52
3.
Ensure each outrigger pad is in firm contact over
its entire surface area, with a suitable supporting
surface! Make adjustments if necessary using
manual outrigger controls.
4.
Operate all non drive functions as described in
their respective sections.
Each outrigger pad must be in firm contact
with the ground for most aerial platform
Drive functions are disabled if the outriggers
are in any position other than fully
If alarm sounds during operation, the
aerial platform is not level or an outrigger
does not have firm ground contact.
Lower the platform immediately! Make
the necessary adjustments to level the
3.8-10c
1.
Ensure platform is fully lowered.
2.
On outrigger control console, select and hold
"
" enable switch to provide power to outrigger
circuit.
" extend
3.
Auto Retraction: Select auto-level switch to
"
" retract position until outriggers are fully
retracted.
Manual Retraction: Select corresponding pairs
of outrigger extend/retract switch to "
position until outriggers are fully retracted.
Limit switches are used to protect outriggers
from being damaged. If drive functions are
not available, visually check to see that all
Section 3 - Operation
NOTE
functions to work.
NOTE
retracted.
WARNING
aerial platform.

To Retract Outriggers

NOTE
outriggers are fully retracted.
Mid Size & Full Size RTs