Locally Concentrated Pressure (Lcp); Overall Uniform Pressure (Oup) - Skyjack SJ 7135 Operating Manual

Mid-size & full-size rough terrain series
Table of Contents

Advertisement

Tables

Locally Concentrated Pressure (LCP):

Foot Print Area = Length x Width
π D
or =
4
Weight of Aerial Platform + Capacity
LCP = 0.4 x
Length
Page 66
Floor Loading Pressure
2
(for outriggers)
Foot Print Area
Width
Diameter (D)

Overall Uniform Pressure (OUP):

Base Area = Length x Width
Weight of Aerial Platform + Capacity*
OUP =
* Capacity for max OUP only.
Width
Width
Length
Section 4
Base Area
Length
Mid Size & Full Size RTs
Engine Powered

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj 8831Sj 7127Sj 8841Sj 9250Sr2584Sr4084 ... Show all

Table of Contents