Visual & Maintenance Inspection
Typical Model 71xx shown
Electrical Panel
Main Power
Disconnect Switch
Load/Tilt
Sensor
Motion Control Manifold
• Manifolds
-
Ensure all fittings and hoses are properly
tightened and there is no evidence of
hydraulic leakage.
-
Ensure there are no loose wires or
missing fasteners.
• Electrical Panel
-
Ensure panel is properly secured and
there is no visible damage.
-
Ensure there are no loose wires or
missing fasteners.
• Load/Tilt Sensor
-
Ensure load/tilt sensor is properly secured
and there is no visible damage.
• Hydraulic Tank (Models 92xx)
-
Ensure hydraulic filler cap is secure.
-
Ensure tank shows no visible damage
and no evidence of hydraulic leakage.
Page 18
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Cushion Cylinder
contained in this operating manual and on the aerial platform.
Section 2 - Familiarization
Emergency Lowering
Access Rod
Main Manifold
Brake Manifold
• Hydraulic Oil
-
Ensure platform is fully lowered, and
outriggers retracted, and then visually
inspect the sight gauge located on the
side of the hydraulic oil tank. Check oil
level against label that indicates minimum
and maximum oil levels (Models 92xx).
-
The hydraulic oil level should be at or
slightly above the top mark of the sight
glass (Models 71xx & 88xx).